Bauman Community Pool
2400 PARK LAWN PL, Middleton, WI 53562 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 72941-81096
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 4 | 0 |
| 2025 | 1 | 4 | 0 |
| 2024 | 1 | 5 | 0 |
| 2023 | 1 | 5 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jun 16, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
30e - SOAP (Pf)
The soap dispensers in shower rooms are empty.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken:
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
A pipe in the pump room above the backwash return piping is dripping. The waterslide into the diving well is leaking from the bottom of the middle area of the slide.
Correction: Properly locate, install, maintain and repair equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Other
41a - MISCELLANEOUS
There is a gap greater than 4 inches at the bottom of perimeter fence, near the sheds.
Correction: Fences serving as barriers shall have no opening greater than 4 inches in width or diameter. The bottom of a fence or wall shall be a maximum of 4 inches from grade.
Code SPS 390.18(4)
-
Not serious
Action taken:
-
Jun 30, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Chemical storage room door is not marked to indicate authorized personnel only and a list of emergency numbers was not present in the room.
Correction: Lock doors to chemical storage areas and mark door to indicate entry is for authorized personnel only. Provide a list of emergency telephone numbers in the chemical storage room or have readily available.
Code ATCP 76.12(2)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator is not documenting testing of interlock system per requirements in ATCP 76.13(1)(c). Operator able to verbally explain system and states interlock testing occurs during backwashing, which occurs more than once a month.
Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system. Documentation shall include the date, results, and the name of the person performing the test.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
28e -REPORTS AND RECORDS (Pf)
Operator is not using department provided report for logging of chemical testing.
Correction: The pool operator or responsible supervisor shall complete reports of the pool operation on forms provided by the department or its agent to include verification and documentation of all of the following: (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety
Code ATCP 76.32(1)
-
Not serious
Action taken:
29f - DEPTH MARKINGS VISIBLE (Pf)
Some of the depth markings along the edge of the pool are fading or worn away.
Correction: Repair the markings so they are clearly visible and readable.
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
-
Jun 25, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
11a - CHEMICAL - LABELING
Large acid tank is not properly labeled.
Correction: Label the chemical container according to ATCP 76.12(1). Containers shall be conspicuously labeled with the following information: (a) Name of the product. (b) The manufacturer’s name and address. (c) Active ingredients. (d) Directions for use. (e) Hazardous ingredient warning. (f) The U.S. environmental protection agency registration number.
Code ATCP 76.12(1)
-
Not serious
Action taken: Pool had been very recentl
Corrected on site
16a - pH
The pH is < 7.0; solution is much yellower than 7.0 level of Taylor test kit.
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Action taken:
26f - PATRON LOAD - NOT POSTED
The maximum patron load is not posted.
Correction: Post the maximum patron load.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken: Operator removed ring buoy
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE
Ring buoy is provided but does not have a rope attached.
Correction: When providing a ring buoy, buoy shall be be attached to a 1/4 inch rope having a length not less than 1.5 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(a)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
Eye wash is missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.
Code ATCP 76.27(1)
-
Not serious
Action taken:
-
Jun 27, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: shepherd's crook moved to
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE
Shepherd's crook is onsite but not readily accessible.
Correction: Mount shepherd's crook in a readily accessible location.
Code ATCP 76.26(1)(a)
-
Not serious
Action taken:
29b - BASIN DEFECTS
The pool basin is in disrepair near gutter at lower lifeguard chair area.
Correction: Repair the pool basin so it is finished and easily cleanable.
Code ATCP 76.33(1)(a)
-
Not serious
Action taken: pool deck to be repaired i
31a - WALLS, CEILING AND FLOORS
Concrete pool deck in disrepair in area between diving board and drop slide.
Correction: Maintain the pool deck in good repair and clean condition.
Code ATCP 76.33(1)(c)
-
Not serious
Action taken:
31b - EQUIPMENT NOT MAINTAINED
Pressure gauge for high rate sand filter #4 is not being maintained and repaired as necessary.
Correction: Repair/replace and maintain pressure gauge for filter #4.
Code ATCP 76.33(1)(e)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available onsite for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. From previous inspection report, Aquastar main drain covers (10 year lifespan) were installed in 2020.
Correction: Maintain documentation of VGBA covers for main drain and equalizers onsite and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: shepherd's crook moved to
Corrected on site
-
Aug 19, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 30, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 13, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 19, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 20, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 23, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 16, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 10, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 25, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 3, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.