RecordWell Data

Van Buren Place Apartment Homes

1351 O'KEEFFE AVE, Sun Prairie, WI 53590 · Dane County

17cited violations
0serious tier
7inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2020-00141
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026140
2025150
2024120
2023110
2022150
2021100
2020100

Inspections

  1. Jul 10, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      An elastic bandage, resuscitation pocket face mask, and eye wash solution are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      There are some missing tiles in the pool basin.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

  2. Jul 29, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for combined chlorine and cyanuric acid are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test combined chlorine at least twice a week. Test cyanuric acid level at least once a week.

      Code ATCP 76.18(1)

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA (P)

      The pool was not closed by the operator or responsible supervisor under the following condition: screw missing on main drain cover causing an immediate danger to safety.

      Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.

      Code ATCP 76.30

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      There are some missing tiles in the pool basin.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      1. There is some rusting of the base post of the pool gate near the entrance to the pool enclosure. 2. There is some piping above the pump that is leaking.

      Correction: Properly locate, install, maintain and repair equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date. The equalizer covers were due for replacement August 2024 and were not replaced.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Replace the equalizer covers.

      Code ATCP 76.38

  3. Jul 19, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for combined chlorine and cyanuric acid are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test combined chlorine concentration at least twice a week. Test cyanuric acid concentration at least once a week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      There is some rusting of the base post of the pool gate near the entrance to the pool enclosure.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

  4. Aug 15, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for combined chlorine and cyanuric acid are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test combined chlorine level at least twice a week. Test cyanuric acid level at least once a week.

      Code ATCP 76.18(1)

  5. Aug 15, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The skimmer weir is missing from the skimmer by the Spa.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential could not be determined at the time of the inspection, because the ORP machine is out of order.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 80 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for Free Chlorine and pH is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Two hand rails by the pool entrance are loose and not being maintained and repaired as necessary.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

  6. Jun 18, 2021 Routine Inspection · Reinspection Required

    No violations cited.

  7. Jun 17, 2020 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.