Westbridge Neighborhood Pool
747 WESTBRIDGE TRL, Waunakee, WI 53597 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2015-00200
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 10 | 0 |
| 2025 | 1 | 7 | 0 |
| 2024 | 1 | 3 | 0 |
| 2023 | 1 | 5 | 0 |
| 2022 | 1 | 3 | 0 |
| 2021 | 1 | 0 | 0 |
| 2018 | 2 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2015 | 2 | 0 | 0 |
Inspections
-
Jul 9, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals are improperly stored in accordance with ATCP 76.12(2) - #1) chemical storage areas must be locked and #2) an "Authorized Personnel Only" sign must be posted on the door to chemical storage areas.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf)
The water testing frequency is not in compliance with ATCP 76.18(1) #1) test and record cyanuric acid 1x per week #2) test and record combine chlorine 2x per week #3) water testing results must be recorded on the form provided by DATCP (Sanitarian will email the form to Adam).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf)
The water testing frequency for [chemical] is not in compliance with ATCP 76.18(1). The daily, weekly and monthly tests must be recorded on a form provided by the Department (DATCP). Sanitarian will provide the required form via email.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken:
23b - NO CPO (Pf)
The facility is not staffed with a current certified pool operator.
Correction: Acquire or train a certified pool operator for the facility.
Code ATCP 76.20(2)(a)
-
Not serious
Action taken:
23c - NO CPO CERTIFICATE (Ppf)
The facility is staffed with a current certified pool operator but the documentation is not available onsite.
Correction: Provide documentation of the certified pool operator for the facility.
Code ATCP 76.20(2)(c)
-
Not serious
Action taken:
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken:
27b - SIGNAGE - SUPERVISION OF CHILDREN
Statement indicating that children under the age of 12 shall be supervised by an adult is missing from signage.
Correction: Add statement/add signage indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b). The age specification on the signage can be greater than 12; for example, if the sign stated "Children under the age of 14 shall be supervised by an adult" this would be more restrictive and thus will meet the requirement.
Code ATCP 76.29(1)(c)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Other
Corrected on site
41a - MISCELLANEOUS
In the lap pool, one of the two drain covers is missing a fastener, and the other main drain cover is missing two fasteners.
Code 76.30(1)(a.) Pool Closing Criteria
-
Not serious
Action taken:
-
Jul 28, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals are improperly stored in accordance with ATCP 76.12(2) - #1) chemical storage areas must be locked and #2) an "Authorized Personnel Only" sign must be posted on the door to chemical storage areas.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf)
The water testing frequency is not in compliance with ATCP 76.18(1) #1) test and record cyanuric acid 1x per week #2) test and record combine chlorine 2x per week #3) water testing results must be recorded on the form provided by DATCP (Sanitarian will email the form to Adam).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken:
23c - NO CPO CERTIFICATE (Ppf)
The facility is staffed with a current certified pool operator but the documentation is not available onsite.
Correction: Provide documentation of the certified pool operator for the facility.
Code ATCP 76.20(2)(c)
-
Not serious
Action taken:
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken:
27b - SIGNAGE - SUPERVISION OF CHILDREN
Statement indicating that children under the age of 12 shall be supervised by an adult is missing from signage.
Correction: Add statement/add signage indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b). The age specification on the signage can be greater than 12; for example, if the sign stated "Children under the age of 14 shall be supervised by an adult" this would be more restrictive and thus will meet the requirement.
Code ATCP 76.29(1)(c)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Aug 1, 2024 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1) - test and record the combined chlorine 2x/week (and cyanuric acid 1x/week if stabilizer is added to the pool or present in the chlorine added to the pool).
Code ATCP 76.18(1)
-
Not serious
Action taken:
30e - SOAP
The soap dispenser in the men's shower is empty.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Other
41a - MISCELLANEOUS
One of the two main drains in the deep end of the main pool does not have any fasteners to secure it to the pool bottom. The fasteners in the other main drain are clearly visible. Adam called Badger Pools to have this corrected. Pool Closed notices were put around the perimeter of the pool and attendant is aware pool cannot be used until corrected.
Correction: Securely fasten the drain cover to the pool.
Code 76.30(1)(a.) Pool Closing Criteria
-
Not serious
Action taken:
-
Aug 9, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
11e - SDS AVAILABILITY
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for [chemical] is not in compliance with ATCP 76.18(1). Combined chlorine shall be tested 2x/week; alkalinity and cyanuric acid shall be tested 1x/week.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
Items are missing from the first aid kit: 4x4 gauze pads, 8x10 gauze pads, elastic bandage, eye wash, pocket face mask, cold packs.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
Biohazard safety kit is located on the premises, however, most of the contents are missing.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 26, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
16b - CYANURIC ACID
The cyanuric acid concentration is 40ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for combined chlorine and cyanuric acid are not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record readings for combined chlorine 2x/week and cyanuric acid 1x/week.
Code ATCP 76.18(1)
-
Not serious
Action taken:
30e - SOAP
The soap dispenser in the men's shower area is empty.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken:
-
Jun 10, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 18, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 5, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 5, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 11, 2015 Reinspection · No Reinspection Required
No violations cited.
-
Jul 2, 2015 Pre-Inspection · Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.