RecordWell Data

Westbridge Neighborhood Pool

747 WESTBRIDGE TRL, Waunakee, WI 53597 · Dane County

11cited violations
0serious tier
10inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2015-00202
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026120
2025110
2024100
2023130
2022150
2021100
2018200
2017100
2015100

Inspections

  1. Jul 9, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      The bottom edge of the activity pool coping (the transition between the deck and the sidewall of the basin) has some cracking, deterioration and a noticeable chunk of concrete is hanging just above the waterline (the concrete is embedded in a plastic strip and not free enough to remove).

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf)

      On the east side of the activity pool, there is a round metal cylinder projecting up from the deck and is a trip hazard. Repair/remove the item so it is not a trip hazard.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

  2. Jul 28, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf)

      On the east side of the activity pool, there is a round metal cylinder projecting up from the deck and is a trip hazard. Repair/remove the item so it is not a trip hazard.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

  3. Aug 1, 2024 Routine Inspection · No Reinspection Required

    No violations cited.

  4. Aug 9, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 558 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for [chemical] is not in compliance with ATCP 76.18(1). Combined chlorine shall be tested 2x/week; alkalinity and cyanuric acid shall be tested 1x/week.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jul 26, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for combined chlorine and cyanuric acid are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record readings for combined chlorine 2x/week and cyanuric acid 1x/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      23b - NO CPO

      The facility is not staffed with a current certified water attraction operator.

      Correction: Acquire or train a certified water attraction operator for the facility.

      Code ATCP 76.20(2)(a)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN

      The facility does not have a lifeguard and/or attendant staffing plan.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.

      Code ATCP 76.22(1)(a)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      Section of pool basin/wall is in disrepair and a chunk of concrete is loosely attached.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  6. Jun 10, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Jul 18, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 5, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jun 5, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jul 2, 2015 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.