Westbridge Neighborhood Pool
747 WESTBRIDGE TRL, Waunakee, WI 53597 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2015-00202
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 1 | 1 | 0 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 3 | 0 |
| 2022 | 1 | 5 | 0 |
| 2021 | 1 | 0 | 0 |
| 2018 | 2 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
Inspections
-
Jul 9, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
29b - BASIN MAINTENANCE AND REPAIR
The bottom edge of the activity pool coping (the transition between the deck and the sidewall of the basin) has some cracking, deterioration and a noticeable chunk of concrete is hanging just above the waterline (the concrete is embedded in a plastic strip and not free enough to remove).
Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.
Code ATCP 76.33(1)(a)
-
Not serious
Action taken:
29d - DECK MAINTENANCE AND CLEANING (Pf)
On the east side of the activity pool, there is a round metal cylinder projecting up from the deck and is a trip hazard. Repair/remove the item so it is not a trip hazard.
Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
-
Jul 28, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
29d - DECK MAINTENANCE AND CLEANING (Pf)
On the east side of the activity pool, there is a round metal cylinder projecting up from the deck and is a trip hazard. Repair/remove the item so it is not a trip hazard.
Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
-
Aug 1, 2024 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 9, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 558 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for [chemical] is not in compliance with ATCP 76.18(1). Combined chlorine shall be tested 2x/week; alkalinity and cyanuric acid shall be tested 1x/week.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 26, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for combined chlorine and cyanuric acid are not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record readings for combined chlorine 2x/week and cyanuric acid 1x/week.
Code ATCP 76.18(1)
-
Not serious
Action taken:
23b - NO CPO
The facility is not staffed with a current certified water attraction operator.
Correction: Acquire or train a certified water attraction operator for the facility.
Code ATCP 76.20(2)(a)
-
Not serious
Action taken:
24a - LIFEGUARD - STAFFING PLAN
The facility does not have a lifeguard and/or attendant staffing plan.
Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.
Code ATCP 76.22(1)(a)
-
Not serious
Action taken:
29b - BASIN DEFECTS
Section of pool basin/wall is in disrepair and a chunk of concrete is loosely attached.
Correction: Repair the pool basin so it is finished and easily cleanable.
Code ATCP 76.33(1)(a)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jun 10, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 18, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 5, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 5, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 2, 2015 Pre-Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.