RecordWell Data

Baymont Inn & Suites

8102 EXCELSIOR DR, Madison, WI 53717 · Dane County

33cited violations
0serious tier
17inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
27867-12901
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262200
2024100
20232110
2022120
2021100
2020100
2018100
2017200
2015200
2013300
2012100

Inspections

  1. Apr 8, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator is not following a combined chlorine plan. The combined chlorine in the whirlpool is 2.0ppm, testing is not being completed at least once daily, and records are not maintained for fresh water added or for dates and times for breakpoint chlorination, and any complaints of eye or respiratory irritation.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Door chain locked to preve

      34d - DOOR/GATE (P) - Not Corrected

      The court doors to the pool enclosure are not self-latching and the door locks do not function.

      Correction: Repair the door immediately so that it is self-closing, latching, and lockable.

      Code ATCP 76.34(4)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      Pump curve onsite may not match the recirculation pump that is installed based on flow rate and photos provided to pool company.

      Correction: Provide a pump curve that matches the recirculation system that is installed. If recirculation pump requires modification, submit pool plans to Wisconsin Department of Safety Professionals from a licensed architect or engineer.

      Code ATCP 76.38

  2. Mar 23, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken: Replaced during inspection Corrected on site

      04c - SKIMMER BASKET/WEIR

      The skimmer weir is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      08d - RECIRCULATION RATE - WHIRLPOOL (Pf)

      The whirlpool has a maximum turnover rate of greater than 30 minutes.

      Correction: Adjust or repair the equipment so the turnover rate does not exceed 30 minutes.

      Code ATCP 76.11(4)(c)

    • Not serious Action taken:

      10b - BACKWASH - SAND FILTER (Pf)

      Backwash procedures are not conspicuously posted in the filter area.

      Correction: Post pool backwash procedures in a conspicuous place in the filter area and backwash the sand filter in accordance manufacturer's instructions.

      Code ATCP 76.11(6)(a)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Doors to chemical storage area is not marked to indicate entry is for authorized personnel only.

      Correction: Mark doors to chemical storage area for authorized personnel only.

      Code ATCP 76.12(2)

    • Not serious Action taken: Recalibrated during inspec Corrected on site

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 578mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 900 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator is not following a combined chlorine plan. The combined chlorine in the whirlpool is 2.0ppm, testing is not being completed at least once daily, and records are not maintained for fresh water added or for dates and times for breakpoint chlorination, and any complaints of eye or respiratory irritation.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf)

      The water testing frequency for combined chlorine and alkalinity are not in compliance with ATCP 76.18(2).

      Correction: Perform water testing in accordance with ATCP 76.18(2). Test combined chlorine in whirlpool once per day and test alkalinity in whirlpool once per week.

      Code ATCP 76.18(2)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS (P)

      The hose bibb in the pump room is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      22a - THERMOMETER (Pf)

      There is no functional or visible thermometer installed on the pool water return line.

      Correction: Install a working thermometer on the pool water return line.

      Code ATCP 76.19(4)(a)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Triangle bandage, scissors, adhesive tape, eye wash, and CPR mask are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      26s - BLANKETS MISSING (Pf)

      2 conventional or emergency blankets are not available in the pool area. One emergency blanket available in the first aid kit.

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken: Updated operating report p

      28e -REPORTS AND RECORDS (Pf)

      Operating report used does not include documentation of interlock testing and safety and rescue equipment maintenance.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      Top stair has a spot of rust and corrosion and a there are a few chipped tiles around the perimeter of the basin.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS

      Pump room walls are crumbling and have surface damage.

      Correction: Maintain the walls, ceilings, and floors in good repair.

      Code ATCP 76.33(1)(c)

    • Not serious Action taken: Door chain locked to preve

      34d - DOOR/GATE (P)

      The court doors to the pool enclosure are not self-latching and the door locks do not function.

      Correction: Repair the door immediately so that it is self-closing, latching, and lockable.

      Code ATCP 76.34(4)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      Pump curve onsite may not match the recirculation pump that is installed based on flow rate and photos provided to pool company.

      Correction: Provide a pump curve that matches the recirculation system that is installed. If recirculation pump requires modification, submit pool plans to Wisconsin Department of Safety Professionals from a licensed architect or engineer.

      Code ATCP 76.38

  3. Jul 25, 2024 Re-Inspection · No Reinspection Required

    No violations cited.

  4. Dec 27, 2023 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      16d - COMBINED CHLORINE - Not Corrected

      The combined chlorine is 1.4.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      29b - BASIN DEFECTS - Not Corrected

      The pool basin finish has not been maintained. Walls, seating, and floor areas appear discolored or are missing finish.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED - Not Corrected

      Chlorine and acid tubing is not being maintained and repaired as necessary. Feeder equipment is heavily rusted and covers missing. Pool stair handrails are discolored below water line.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      Documentation provided indicates main drain cover and equalizer covers are expired.

      Correction: Replace main drain cover and equalizer covers. Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Dec 8, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      Weir is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16d - COMBINED CHLORINE

      The combined chlorine is 1.4.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2 times per week.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      The pool basin finish has not been maintained. Walls, seating, and floor areas appear discolored or are missing finish.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Chlorine and acid tubing is not being maintained and repaired as necessary. Feeder equipment is heavily rusted and covers missing. Pool stair handrails are discolored below water line.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Other

      34e - VGBA COVERS

      Documentation provided indicates main drain cover and equalizer covers are expired.

      Correction: Replace main drain cover and equalizer covers. Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  6. Dec 7, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16d - COMBINED CHLORINE

      The combined chlorine is 2ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

  7. Aug 25, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Mar 10, 2020 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Dec 18, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Dec 20, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Mar 31, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Nov 13, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Jan 8, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Oct 17, 2013 Reinspection · No Reinspection Required

    No violations cited.

  15. Oct 1, 2013 Reinspection · Reinspection Required

    No violations cited.

  16. Sep 17, 2013 Routine Inspection · Reinspection Required

    No violations cited.

  17. Dec 11, 2012 Routine Inspection · Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.