1 Glenn Place
5351 NOBEL DR, Fitchburg, WI 53711 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2022-00356
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 1 | 2 | 0 |
| 2024 | 2 | 1 | 0 |
| 2022 | 1 | 2 | 0 |
Inspections
-
Aug 4, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
05b - WATER LEVEL (Pf)
The pool water level is an inch or two elevated and is not allowing for continuous effective surface skimming.
Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continous water supply over the gutter.
Code ATCP 76.11(2)(a) and ATCP 76.19(3)
-
Not serious
Action taken: Operator reconnected pool
Corrected on site
26n - TELEPHONE - NOT WORKING (P)
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken:
-
Jul 17, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
05b - WATER LEVEL (Pf)
The pool water level is not adequate for continuous effective surface skimming. Water level about two inches high.
Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continous water supply over the gutter.
Code ATCP 76.11(2)(a) and ATCP 76.19(3)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 50 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken:
-
Aug 13, 2024 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 11, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Operator instructed to hav
Corrected on site
20e - WATER TESTING FREQUENCY - ORP
The water testing frequency for pH and disinfectant is not in compliance with ATCP 76.18(3), as chemicals are not being tested once daily on the weekends.
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: Operator instructed to hav
Corrected on site
-
May 27, 2022 Pre-Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket is not located on site. There are spare baskets available for the pump.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken: CPO adjusted pool, disinfe
Corrected on site
14c - CHLORINE TOO HIGH
The chlorine residual exceeds 10 ppm. The pool is currently not open to the public.
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.
Code ATCP 76.14(4)(f)
-
Not serious
Action taken:
Source: Public Health Madison & Dane County. History last read Nov 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.