Candlewood Suites

4862 Hayes RD, Madison, WI 53704 · Dane County

18cited violations
0serious tier
3inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2025-00808
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262140
2025140

Inspections

  1. Oct 8, 2026 Re-Inspection · Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET - Not Corrected

      A spare strainer basket(s) or screen for the skimmers or the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      09a - FLOW METER (P - Not Corrected

      The flow meter is not functional or installed properly.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf) - Not Corrected

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected

      Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf) - Not Corrected

      Ecolab controller does not show the water potential in mV.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

  2. Sep 23, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers or the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional or installed properly.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf)

      Ecolab controller does not show the water potential in mV.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16a - pH (P)

      pH was at or below the lowest measurable range of the test kit (7.0); the sample color was lighter/brighter yellow than the 7.0 comparator standard.

      Correction: Maintain the pH between 7.2 and 7.8.

      Code ATCP 76.14(5)(c)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The ORP controller does not display ORP in mV, so the water testing frequency for chlorine and pH are not in compliance with ATCP 76.18(1).

      Correction: Until the ORP controller is displaying water potential between 650-950mV, test chlorine and pH twice a day.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf)

      The emergency numbers and/or the facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near or attached to the designated emergency phone.

      Code ATCP 76.26(2)(d)

  3. Dec 29, 2025 Pre-Inspection · No Reinspection Required
    • Not serious Action taken

      06a - SPARE STRAINER BASKET

      Spare strainer baskets for the skimmers and recirculation pump are not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional or installed properly.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      The test kit reagents are not stored properly, replaced as required, or being used past their expiration date. Multiple reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

Source: Public Health Madison & Dane County. History last read Nov 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.