12cited violations
0serious tier
4inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2021-00095
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026140
2025140
2023240

Inspections

  1. Jun 4, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 50.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: Sanitarian provided the DA Corrected on site

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Operator obtained reagent Corrected on site

      20b - TEST KIT REAGENT STORAGE (Pf)

      A test kit reagents is expired. - the FAS DPD titrating reagent.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

  2. Aug 26, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 50.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: Sanitarian provided the DA Corrected on site

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Operator obtained reagent Corrected on site

      20b - TEST KIT REAGENT STORAGE (Pf)

      A test kit reagents is expired. - the FAS DPD titrating reagent.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

  3. Jul 25, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      08e- RECIRCULATION RATE - THERAPY/EXERCISE

      The therapy or exercise pool exceeds the required turnover rate indicated in Table ATCP 76.11-B. Turnover rate at time of inspection is 1.6 hours. Per ATCP 76.11-B, turnover rate shall be 1 hour or less.

      Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(e)

    • Not serious Action taken:

      16a - pH

      The pH is 7.0.

      Correction: Adjust the pH between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

  4. Jan 18, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken: (Maximum turnover rate for

      08e- RECIRCULATION RATE - THERAPY/EXERCISE

      The therapy or exercise pool exceeds the required turnover rate indicated in Table ATCP 76.11-B.

      Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(e)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE

      Chemicals are improperly stored in accordance with ATCP 76.12(2). Chlorine and acid are stored side by side in pump room without any spill protection.

      Correction: Store chemicals in accordance with ATCP 76.12(2). Provide overspill protection to prevent accidental mixing of chlorine and acid.

      Code ATCP 76.12(2)

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.