Belleville School District Pool
625 W CHURCH ST, Belleville, WI 53508 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 73294-81513
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 8 | 0 |
| 2024 | 1 | 1 | 0 |
| 2023 | 1 | 3 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jul 13, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional as the bobber is stuck or the markers are worn and cannot be read.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot demostrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken: Complete template and send
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
24a - LIFEGUARD - STAFFING PLAN (Ppf)
Update the staffing plan to include patron load with diagrams. In diagrams, at most, 5 lifeguards are staffed, clarify max patron load is 236 at this capacity when diving board and rock wall is open. Additional guard required to increase patron load.
Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.
Code ATCP 76.22(1)
-
Not serious
Action taken: PIC relieved staff with ex
25l - ATTENDANT SERVING AS LIFEGUARD
Most staff completed lifeguard certification course through the Red Cross in spring of 2025 and the CPR component is only valid for 1 year. Two lifeguards onsite and on duty during the inspection have Red Cross Certifications issued 3/2026.
Correction: The individuals must be relieved of duties until a lifeguard meeting the definition of ATCP 76.22(2). If the minimum lifeguard requirements in the approved staffing plan are not met as a result, the guarded pool or portion must be closed.
Code ATCP 76.22(2)(b)
-
Not serious
Action taken:
26t - BIOHAZARD SAFETY KIT (Pf)
No biohazard safety kit is located at the first aid station or on the premises.
Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)
-
Not serious
Any of the following conditions or situa
Corrected on site
28a - CLOSING CRITERIA (P)
The pool was not closed by the operator or responsible supervisor under the following conditions: (c). There are several days in the logs were the pool chlorine residual was tested and documented as <1.0ppm without any corrective action noted. (e) staff with expired CPR certifications were serving as lifeguards.
Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.
Code ATCP 76.30
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken:
-
Jul 3, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Send updated plan to sanit
24a - LIFEGUARD - STAFFING PLAN
1) The lifeguard and attendant staffing plan is missing diagrams including the placement of attendants and lifeguards for various usages of the pool. Include the guard configuration for diving board and rock wall. 2) As doors are not self-closing and self-latching, plan does not include that the entrance to the pool shall be staffed with an attendant and at least one lifeguard shall be present.
Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.
Code ATCP 76.22(1)(a)
-
Not serious
Action taken: Send updated plan to sanit
-
Aug 7, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain covers showing model, installation, and replacement date. Employee previously dove down to observe main drain, current make installed is Waterway and has a life expectancy of 7 years. Pool is closing next week for the season.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Other
41a - MISCELLANEOUS
According to inspection history, pool changed from bromine to chlorine for 2017 season requiring DSPS plan review. Documentation of approval letter is not available onsite.
Correction: Submit pool modification plans to the Wisconsin department of safety and professional services pursuant to ch. SPS 390. Documentation shall be made available to the department upon request.
Code ATCP 76.04(2)
-
Not serious
Action taken:
-
Jul 12, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 17, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
May 24, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 20, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 29, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 10, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 24, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 10, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 8, 2012 Routine Inspection · No Reinspection Required
No violations cited.