RecordWell Data

Super 8

1622 N BROADWAY, Menomonie, WI 54751 · Dunn County

6cited violations
0serious tier
3inspections

Establishment

Type
Pool / recreational water (Whirlpool)
Inspected by
Dunn County Health Department
License / ID
DKRR-CCDSFB
Status
Permitted
Phone
(630) 440-7995
Official record
Dunn County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026130
2025120
2024110

Inspections

  1. Feb 4, 2026 Routine · 3 non-critical
    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL TEST ONE OTHER TIME DURING PEAK PATRON LOAD, PH AND SANITIZER; NO AUTOMATIC CONTROLLER

      Whirlpool water not tested for pH and disinfectant at least two (of the total of 4) times during the day’s peak patron load.

      Correction: Test pool water for pH and disinfectant at least two (of the total of 4) times during the day’s peak patron load.

      Code ATCP 76.18(2)(a)2.- WATER TESTED TOTAL OF 4 TIMES WHIRLPOOL,

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY

      Whirlpool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

  2. Apr 16, 2025 Routine · 2 non-critical
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met because the flow meters are hard to read and need to be replaced with new flow meters.

      Correction: Notified the person in charge. The PIC will replace with new flow meter to ensure turnover rate is correct.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition. It is hard to read the flow meter.

      Correction: Notified person in charge. PIC wil Install new flow meter

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

  3. Jan 23, 2024 Routine · 1 non-critical
    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

Source: Dunn County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.