  1. Jul 14, 2026 Re-inspection 2 · 2 non-critical
    • Not serious Non-critical

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      Due to 2 or more re-inspections in a 3-year period, it is required that the facility have a staff member obtain a certified pool operator (CPO) certificate.

      Correction: Provide a certified operator for the pool within 90 days by October 12, 2026. If not obtained within 90 days the pool may be closed until the certified poool operator certificate is obtained.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Not serious Non-critical

      WATER HEATERS-MAINTAINED OPERATIONAL

      Water heater has a red tag from Xcel Energy that the water heater needs to be serviced

      Correction: Maintain water heater or heat exchanger in operating condition.

      Code ATCP 76.33(4)(a) - MAINTAINED

  2. Jul 2, 2026 Re-inspection · 4 non-critical, 2 repeat
    • Not serious Non-critical

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is not providing proper turnover rate and is mostly from the main drain.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met and is at 9.1 hour turnover rate

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate. Turnover rate should be at 6 hours or less.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat

      PUMP, CONTINUOUS OPERATION

      The pump is not operated continuously to continuously achieve the designed recirculation rate. Flow meters are not working to obtain turnover rate

      Correction: Operate the pump continuously to achieve the designed recirculation rate.

      Code ATCP 76.11(4)(b) - PUMP CONTINUOUS OPERATION

    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition. The flow meter is not working.

      Correction: Adjust or repair the flow meter

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

  3. Jun 12, 2026 Routine · 6 critical, 6 non-critical, 1 repeat
    • Not serious Non-critical

      PUMP, CONTINUOUS OPERATION

      The pump is not operated continuously to continuously achieve the designed recirculation rate. Flow meters are not working to obtain turnover rate

      Correction: Operate the pump continuously to achieve the designed recirculation rate.

      Code ATCP 76.11(4)(b) - PUMP CONTINUOUS OPERATION

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition. The flow meter is not working.

      Correction: Adjust or repair the flow meter

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      BACKWASH PROCEDURES POSTED ON EASILY READ CHART

      The backwash procedure is no conspicuously posted on an easily read chart.

      Correction: Post the backwash procedure on an easily read chart.

      Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is [260 ] mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      OPERATOR RESPONSIBILITIES

      The operator has not been responsible for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality pursuant.

      Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.

      Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0 for chlorine

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      PH

      The pH is 6.9.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      RESPONSIBLE SUPERVISOR FOR POOL

      The pool does not have a responsible supervisor.

      Correction: Provide a responsible supervisor for the pool.

      Code ATCP 76.21 (1)(a) - RESPONSIBLE SUPERVISOR REQUIRED

    • Serious Critical

      RESPONSIBLE SUPERVISOR POOL CLOSED

      Responsible supervisor is not ensuring that pool is closed pursuant to ATCP 76.30, closing criteria. The chlorine was at 0 ppm

      Correction: Have the responsible supervisor ensure that the pool is closed pursuant to ATCP 76.30, closing criteria. Pool is closed per health inspector

      Code ATCP 76.21 (1)(c)10. - CLOSE POOL

    • Serious Critical

      CLOSING CRITERIA-FAILURE TO MEET 76.16

      The Responsible Supervisor or operator has not closed the pool after failure to comply with the water quality requirements. Chlorine is at 0 PPM

      Correction: Close the pool in the event of failure to comply with the water quality requirements pursuant to s. ATCP 76.16. Pool is closed until health inspector does an inspection after items have been fixed.

      Code ATCP 76.30 (1)(b) - FAILURE TO MEET ATCP 76.16

    • Serious Critical

      CLOSING CRITERIA-NO RESPONSIBLE SUPERVISOR

      The operator has not closed the pool due to the absence or non−availability of a responsible supervisor.

      Correction: Close the pool in the event of absence or non−availability of a responsible supervisor.

      Code ATCP 76.30 (1)(f) - NO RESPONSIBLE SUPERVISOR

  4. Jun 2, 2025 Routine · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat Corrected on site

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Notified the person in charge and provided a copy of a sign that was posted during the inspection.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

  5. Jan 30, 2024 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

Source: Dunn County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.