Americinn Motel-whirlpool
6200 TEXACO DR, Eau Claire, WI 54703 · Eau Claire County
Establishment
- Type
- Pool / recreational water (Whirlpool)
- Inspected by
- Eau Claire City-County Health Department
- License / ID
- VRER-ANWS83
- Status
- Permitted
- Phone
- (715) 597-5000
- Official record
- Eau Claire City-County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 18 | 3 |
| 2025 | 2 | 26 | 4 |
| 2024 | 2 | 20 | 4 |
| 2023 | 2 | 21 | 0 |
Inspections
-
Jun 17, 2026 Routine · 3 critical, 15 non-critical, 9 repeat
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Inlets are observed pointing every which direction.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is missing for the whirlpool.
Correction: Replace the flow meter to whirl pool .
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN ACTION LEVEL
The combined chlorine plan does not include the combined chlorine action level. The combined chlorine level is 6.
Correction: Includes the combined chlorine action level in the combined chlorine plan.
Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
Repeat
CYANURIC TEST
Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.
Correction: Test water for the cyanuric acid at least once a week.
Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC
-
Not serious
Non-critical
TELEPHONE-OTHER TECHNOLOGIES, POWER SUPPLY
Emergency phone in the pool area does not have connection to permanent power supply.
Correction: Provide working phone inside pool.
Code ATCP 76.26(2)(b)1. - TELEPHONE, OTHER TECHNOLOGIES, POWER
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
POOL BASIN ROUTINELY BRUSHED, VACUUMED
Whirlpool basin on the floor observed in need of cleaning with debris and sand build up on bottom.
Correction: Routinely brush or vacuum the pool basin to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration.
Code ATCP 76.33(1)(a)1- POOL BASIN BRUSHED, VACUUMED
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Whirlpool is observed cracked and pitted .
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Repeat
PH
The pH is less than 7.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Serious
Critical
CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE
The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.
Correction: Close the pool in the event of a nonfunctional emergency phone.
Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE
-
Not serious
Non-critical
Repeat
-
Jun 13, 2025 Re-inspection · 2 critical, 11 non-critical, 13 repeat
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
Repeat
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter to whirlpool is broken and not working.
Correction: Adjust or repair the flow meter to determine flow.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN ACTION LEVEL
The combined chlorine plan does not include the combined chlorine action level.
Correction: Includes the combined chlorine action level in the combined chlorine plan.
Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
Repeat
CYANURIC TEST
Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.
Correction: Test water for the cyanuric acid at least once a week.
Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC
-
Not serious
Non-critical
Repeat
THERMOMETER RETURN LINE
An accurate thermometer is not located in the pool water return line.
Correction: Provide an accurate thermometer in the pool water return line.
Code ATCP 76.19(4)(a)1 - THERMOMETER
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED CLEAN AND SANITARY
Whirlpool basin observed with excessive sand on the bottom and in need of cleaning.
Correction: Maintained the pool basin in a clean and sanitary condition.
Code ATCP 76.33(1)(a)3 - POOL BASIN NOT CLEAN AND SANITARY
-
Not serious
Non-critical
Repeat
DRINKING FOUNTAIN MAINTAINED
Observed drinking fountain leaking from bottom.
Correction: Maintain the drinking fountain in working order.
Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN
-
Serious
Critical
Repeat
PH
The pH is less than 7.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
Repeat
-
Jun 11, 2025 Routine · 2 critical, 11 non-critical, 6 repeat
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter to whirlpool is broken and not working.
Correction: Adjust or repair the flow meter to determine flow.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN ACTION LEVEL
The combined chlorine plan does not include the combined chlorine action level.
Correction: Includes the combined chlorine action level in the combined chlorine plan.
Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
CYANURIC TEST
Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.
Correction: Test water for the cyanuric acid at least once a week.
Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC
-
Not serious
Non-critical
THERMOMETER RETURN LINE
An accurate thermometer is not located in the pool water return line.
Correction: Provide an accurate thermometer in the pool water return line.
Code ATCP 76.19(4)(a)1 - THERMOMETER
-
Not serious
Non-critical
POOL BASIN MAINTAINED CLEAN AND SANITARY
Whirlpool basin observed with excessive sand on the bottom and in need of cleaning.
Correction: Maintained the pool basin in a clean and sanitary condition.
Code ATCP 76.33(1)(a)3 - POOL BASIN NOT CLEAN AND SANITARY
-
Not serious
Non-critical
DRINKING FOUNTAIN MAINTAINED
Observed drinking fountain leaking from bottom.
Correction: Maintain the drinking fountain in working order.
Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN
-
Serious
Critical
Repeat
PH
The pH is less than 7.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
Repeat
-
Jul 16, 2024 Re-inspection · 2 critical, 8 non-critical, 10 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS-ADJUSTED
Skimmers not adjusted to ensure vigorous skimming.
Correction: Adjust skimmers to maintain vigorous skimming .
Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter for whirlpool is broke off and there is not a flow meter.
Correction: Replace flow meter for whirlpool.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
PIPING LABELED, TAGGED OR CODED
The piping is not labeled, tagged or color-coded.
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
Repeat
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Whirlpool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. The whirlpool is open to the public and has not been tested yet for the day.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in a [pool] and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Serious
Critical
Repeat
PH
The pH is greater than 8 .
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
Repeat
-
Jun 25, 2024 Routine · 2 critical, 8 non-critical
-
Not serious
Non-critical
SKIMMERS-ADJUSTED
Skimmers not adjusted to ensure vigorous skimming.
Correction: Adjust skimmers to maintain vigorous skimming .
Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED
-
Not serious
Non-critical
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter for whirlpool is broke off and there is not a flow meter.
Correction: Replace flow meter for whirlpool.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
PIPING LABELED, TAGGED OR CODED
The piping is not labeled, tagged or color-coded.
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Whirlpool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. The whirlpool is open to the public and has not been tested yet for the day.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in a [pool] and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Serious
Critical
PH
The pH is greater than 8 .
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
-
Jun 26, 2023 Re-inspection · 9 non-critical, 9 repeat
-
Not serious
Non-critical
Repeat
INLET POSITION
Inlets are not being checked and adjusted to ensure a uniform distribution that provides effective skimming in all areas. Inlets were observed to be pointed in different directions.
Correction: Check and adjust all inlets to ensure a uniform distribution pattern that provides effective skimming in all areas.
Code ATCP 76.11(2)(c)
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
There is not a working flow meter for whirlpool
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
Repeat
MSDS AVAILABILITY
Material safety data sheets are not available for all chemicals used in the facility.
Correction: Provide material safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Non-critical
Repeat
WATER TESTING FREQUENCY - POOLS
The water testing frequency for testing chemicals is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Non-critical
Repeat
IN LINE THERMOMETER
There is no functional thermometer installed on the pool water return line.
Correction: Install a working thermometer on the pool water return line.
Code ATCP 76.19(4)(a)
-
Not serious
Non-critical
Repeat
SKIMMER/MAIN DRAIN RATIO INCORRECT
The skimmer to main drain flow ration is not set correctly.
Correction: Readjust the flow so that only 20% comes through the main drain and 80% comes through the skimmers.
Code [A] ATCP 76.11(2)(a)
-
Not serious
Non-critical
Repeat
SPARE STRAINER BASKET - REQUIREMENT
A spare strainer basket is not located on site.
Correction: Provide a spare basket or screen.
Code [A] ATCP 76.11(2)(d)
-
Not serious
Non-critical
Repeat
FIRST AID KIT UNAVAILABLE
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code [A] ATCP 76.27(1)
-
Not serious
Non-critical
Repeat
BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code [B] ATCP 76.27(1)
-
Not serious
Non-critical
Repeat
-
May 24, 2023 Routine · 12 non-critical
-
Not serious
Non-critical
INLET POSITION
Inlets are not being checked and adjusted to ensure a uniform distribution that provides effective skimming in all areas. Inlets were observed to be pointed in different directions.
Correction: Check and adjust all inlets to ensure a uniform distribution pattern that provides effective skimming in all areas.
Code ATCP 76.11(2)(c)
-
Not serious
Non-critical
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
There is not a working flow meter for whirlpool
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
MSDS AVAILABILITY
Material safety data sheets are not available for all chemicals used in the facility.
Correction: Provide material safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Non-critical
pH OUT OF BALANCE
The pH is great than 8
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Non-critical
CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm. The cholrine in whirlpool is 16.
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range.
Code ATCP 76.14(4)(f)
-
Not serious
Non-critical
WATER TESTING FREQUENCY - POOLS
The water testing frequency for testing chemicals is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Non-critical
IN LINE THERMOMETER
There is no functional thermometer installed on the pool water return line.
Correction: Install a working thermometer on the pool water return line.
Code ATCP 76.19(4)(a)
-
Not serious
Non-critical
PERMISSIBLE PATRON LOAD
The posted maximum patron load is not posted as stated in ATCP 76.25(1).
Correction: Calculate and post the maximum patron load in compliance with ATCP 76.25(1).
Code ATCP 76.25(1)
-
Not serious
Non-critical
SKIMMER/MAIN DRAIN RATIO INCORRECT
The skimmer to main drain flow ration is not set correctly.
Correction: Readjust the flow so that only 20% comes through the main drain and 80% comes through the skimmers.
Code [A] ATCP 76.11(2)(a)
-
Not serious
Non-critical
SPARE STRAINER BASKET - REQUIREMENT
A spare strainer basket is not located on site.
Correction: Provide a spare basket or screen.
Code [A] ATCP 76.11(2)(d)
-
Not serious
Non-critical
FIRST AID KIT UNAVAILABLE
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code [A] ATCP 76.27(1)
-
Not serious
Non-critical
BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code [B] ATCP 76.27(1)
-
Not serious
Non-critical
Source: Eau Claire City-County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.