RecordWell Data

Best Western Plus Conference Center Whirlpool

3340 MONDOVI RD, Eau Claire, WI 54701 · Eau Claire County

46cited violations
1serious tier
6inspections

Establishment

Type
Pool / recreational water (Whirlpool)
Inspected by
Eau Claire City-County Health Department
License / ID
JHAN-CR8HP7
Status
Permitted
Phone
(715) 839-9989
Official record
Eau Claire City-County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20261111
2025190
2024200
20232260

Inspections

  1. Jun 16, 2026 Routine · 1 critical, 10 non-critical, 5 repeat
    • Not serious Non-critical Repeat

      SKIMMER COVERS SECURELY SEATED ON DECK

      Skimmer covers not securely seated on deck. Covers are not secured and no screws for covers.

      Correction: Ensure that skimmer covers are securely seated on deck.

      Code ATCP 76.11(2)(b) 3. - SKIMMER COVERS SECURE ON DECK

    • Not serious Non-critical

      INLETS CHECKED AND ADJUSTED

      Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Inelts are pointed all different directions in whirl pool.

      Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.

      Code ATCP 76.11(2)(c) - INLETS POSITIONED

    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Not serious Non-critical Repeat

      POOL DECK-GOOD REPAIR

      Areas on pool deck where the edge of the pool basin meets the tile is in need of new grout. The grout is missing is some areas along the edges of tile to the pool basin.

      Correction: Maintain pool deck area in good repair, Re grout areas where it is missing to prevent injury.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. I have in the notes the drains were replaced in July 2024. Manager will look for drain cover replacement documents.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      The chlorine level in the whirlpool is .6

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  2. Apr 29, 2025 Routine · 9 non-critical
    • Not serious Non-critical

      SKIMMER COVERS SECURELY SEATED ON DECK

      Skimmer covers not securely seated on deck.

      Correction: Ensure that skimmer covers are securely seated on deck.

      Code ATCP 76.11(2)(b) 3. - SKIMMER COVERS SECURE ON DECK

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Pool deck area missing caulk in areas around the pool and whirlpool

      Correction: re-caulk areas around whirlpool to prevent injury.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

  3. Aug 28, 2024 Re-inspection · No items found

    No violations cited.

  4. Jun 10, 2024 Routine · No items found

    No violations cited.

  5. Apr 26, 2023 Re-inspection · 13 non-critical, 13 repeat
    • Not serious Non-critical Repeat

      SAND FILTER BACKWASHING

      The sand filter is not being backwashed in accordance with ATCP 76.11(6)(b).

      Correction: Backwash the sand filter in accordance with ATCP 76.11(6)(b).

      Code ATCP 76.11(6)(b)

    • Not serious Non-critical Repeat

      MSDS AVAILABILITY

      Material safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide material safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Non-critical Repeat

      IN LINE THERMOMETER

      There is no functional thermometer installed on the pool water return line.

      Correction: Install a working thermometer on the pool water return line.

      Code ATCP 76.19(4)(a)

    • Not serious Non-critical Repeat

      FECAL CONTAMINATION NOT DOCUMENTED

      Documentation of fecal accidents in the facility is missing or incomplete.

      Correction: Document each fecal accident pursuant to ATCP 76.31(2). Provide binder will all required documentation

      Code ATCP 76.31(2)

    • Not serious Non-critical Repeat

      EQUIPMENT NOT MAINTAINED

      Tiles missing on the side of wall by whirlpool is not being maintained and repaired as necessary.

      Correction: Repair and maintain all equipment pursuant to ATCP 76.33(1)(e).

      Code ATCP 76.33(1)(e)

    • Not serious Non-critical Repeat

      IN NEED OF REPAIR

      There is missing caulk around hot tub/pool area is in need of repair. There are sharp edges which can result in injurty

      Correction: Repair and maintain in accordance with recognized safe practices.

      Code ATCP 76.37(1)(a)

    • Not serious Non-critical Repeat

      SKIMMER/MAIN DRAIN RATIO INCORRECT

      The skimmer to main drain flow ration is not set correctly.

      Correction: Readjust the flow so that only 20% comes through the main drain and 80% comes through the skimmers.

      Code [A] ATCP 76.11(2)(a)

    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET - REQUIREMENT

      A spare strainer basket or screen for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code [A] ATCP 76.11(2)(d)

    • Not serious Non-critical Repeat

      MAXIMUM PATRON LOAD NOT POSTED

      The maximum patron load is not posted in the facility.

      Correction: Post the maximum patron load in accordance with ATCP 76.29(1)(d).

      Code [A] ATCP 76.29(1)(d)

    • Not serious Non-critical Repeat

      DECK DISINFECTION

      The deck and appurtenances are not being cleaned and sanitized regularly.

      Correction: Clean and sanitize the deck and appurtenances according to ATCP 76.33 (1)(b).

      Code [A] ATCP 76.33(1)(b)

    • Not serious Non-critical Repeat

      BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code [B] ATCP 76.27(1)

    • Not serious Non-critical Repeat

      MONTHLY OPERATION REPORTS NOT SUBMITTED

      Monthly operation reports are not being submitted in accordance with ATCP 76.32(1).

      Correction: Submit monthly operation reports in accordance with ATCP 76.32(1).

      Code [B] ATCP 76.32(1)

    • Not serious Non-critical Repeat

      RECORD RETENTION

      Pool Records was not available for review.

      Correction: Keep records in accordance with ATCP 76.32(3).

      Code [B] ATCP 76.32(3)

  6. Apr 25, 2023 Pre-inspection · 13 non-critical
    • Not serious Non-critical

      SAND FILTER BACKWASHING

      The sand filter is not being backwashed in accordance with ATCP 76.11(6)(b).

      Correction: Backwash the sand filter in accordance with ATCP 76.11(6)(b).

      Code ATCP 76.11(6)(b)

    • Not serious Non-critical

      MSDS AVAILABILITY

      Material safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide material safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Non-critical

      IN LINE THERMOMETER

      There is no functional thermometer installed on the pool water return line.

      Correction: Install a working thermometer on the pool water return line.

      Code ATCP 76.19(4)(a)

    • Not serious Non-critical

      FECAL CONTAMINATION NOT DOCUMENTED

      Documentation of fecal accidents in the facility is missing or incomplete.

      Correction: Document each fecal accident pursuant to ATCP 76.31(2). Provide binder will all required documentation

      Code ATCP 76.31(2)

    • Not serious Non-critical

      EQUIPMENT NOT MAINTAINED

      Tiles missing on the side of wall by whirlpool is not being maintained and repaired as necessary.

      Correction: Repair and maintain all equipment pursuant to ATCP 76.33(1)(e).

      Code ATCP 76.33(1)(e)

    • Not serious Non-critical

      IN NEED OF REPAIR

      There is missing caulk around hot tub/pool area is in need of repair. There are sharp edges which can result in injurty

      Correction: Repair and maintain in accordance with recognized safe practices.

      Code ATCP 76.37(1)(a)

    • Not serious Non-critical

      SKIMMER/MAIN DRAIN RATIO INCORRECT

      The skimmer to main drain flow ration is not set correctly.

      Correction: Readjust the flow so that only 20% comes through the main drain and 80% comes through the skimmers.

      Code [A] ATCP 76.11(2)(a)

    • Not serious Non-critical

      SPARE STRAINER BASKET - REQUIREMENT

      A spare strainer basket or screen for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code [A] ATCP 76.11(2)(d)

    • Not serious Non-critical

      MAXIMUM PATRON LOAD NOT POSTED

      The maximum patron load is not posted in the facility.

      Correction: Post the maximum patron load in accordance with ATCP 76.29(1)(d).

      Code [A] ATCP 76.29(1)(d)

    • Not serious Non-critical

      DECK DISINFECTION

      The deck and appurtenances are not being cleaned and sanitized regularly.

      Correction: Clean and sanitize the deck and appurtenances according to ATCP 76.33 (1)(b).

      Code [A] ATCP 76.33(1)(b)

    • Not serious Non-critical

      BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code [B] ATCP 76.27(1)

    • Not serious Non-critical

      MONTHLY OPERATION REPORTS NOT SUBMITTED

      Monthly operation reports are not being submitted in accordance with ATCP 76.32(1).

      Correction: Submit monthly operation reports in accordance with ATCP 76.32(1).

      Code [B] ATCP 76.32(1)

    • Not serious Non-critical

      RECORD RETENTION

      Pool Records was not available for review.

      Correction: Keep records in accordance with ATCP 76.32(3).

      Code [B] ATCP 76.32(3)

Source: Eau Claire City-County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.