Autumn Ridge Apartments- Pool
2390 RIDGEVIEW, Eau Claire, WI 54701 · Eau Claire County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- Eau Claire City-County Health Department
- License / ID
- HSAT-7QWGGU
- Status
- Permitted
- Phone
- (715) 835-2888
- Official record
- Eau Claire City-County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 0 |
| 2025 | 1 | 5 | 1 |
| 2024 | 1 | 2 | 0 |
| 2023 | 1 | 3 | 0 |
Inspections
-
Jun 16, 2026 Routine · 1 non-critical
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
-
Jun 17, 2025 Routine · 1 critical, 4 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
CYANURIC TEST
Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.
Correction: Test water for the cyanuric acid at least once a week.
Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair, areas of deep/missing grout causing sharp edges.
Correction: Maintain pool deck area in good repair. Dicussed regrouting deteriorated areas.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Serious
Critical
HOSING - BACKFLOW PREVENTION DEVICE
No backflow preventor provided on hose used for filling.
Correction: Provide backflow.
Code ATCP 76.33(1)(d)2. - BACKFLOW PREVENTION
-
Not serious
Non-critical
-
Jun 11, 2024 Routine · 2 non-critical
-
Not serious
Non-critical
SKIMMERS-ADJUSTED
The skimmer and the main drain are both wide open.
Correction: Adjusted to 80/20 during the inspection. Adjust skimmers to maintain vigorous skimming .
Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-LIFESPAN
The main drain and equilizer covers expired on 7/17/2023.
Correction: Indicate in the log the drain cover life span.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Not serious
Non-critical
-
Jun 14, 2023 Routine · 3 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
Flowmeter stuck and can't determine flow rate.
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
SELF-CLOSING AND LATCHING GATES
The door or gate to the pool enclosure is not self-closing or latching.
Correction: Repair the door immediately so that it is self-closing and latching. (keep door locked until repaired-there is a second entry that is functioning)
Code [A] ATCP 76.34(4)
-
Not serious
Non-critical
CRACKS OR PITTING IN THE POOL BASIN
Pool basin paint coming off.
Correction: Will need to repaint or resurface pool basin.
Code [B] ATCP 76.33(1)(a)
-
Not serious
Non-critical
Repeat
Source: Eau Claire City-County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.