RecordWell Data

Autumn Ridge Apartments- Pool

2390 RIDGEVIEW, Eau Claire, WI 54701 · Eau Claire County

11cited violations
1serious tier
4inspections

Establishment

Type
Pool / recreational water (Swimming)
Inspected by
Eau Claire City-County Health Department
License / ID
HSAT-7QWGGU
Status
Permitted
Phone
(715) 835-2888
Official record
Eau Claire City-County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026110
2025151
2024120
2023130

Inspections

  1. Jun 16, 2026 Routine · 1 non-critical
    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

  2. Jun 17, 2025 Routine · 1 critical, 4 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair, areas of deep/missing grout causing sharp edges.

      Correction: Maintain pool deck area in good repair. Dicussed regrouting deteriorated areas.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical

      HOSING - BACKFLOW PREVENTION DEVICE

      No backflow preventor provided on hose used for filling.

      Correction: Provide backflow.

      Code ATCP 76.33(1)(d)2. - BACKFLOW PREVENTION

  3. Jun 11, 2024 Routine · 2 non-critical
    • Not serious Non-critical

      SKIMMERS-ADJUSTED

      The skimmer and the main drain are both wide open.

      Correction: Adjusted to 80/20 during the inspection. Adjust skimmers to maintain vigorous skimming .

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-LIFESPAN

      The main drain and equilizer covers expired on 7/17/2023.

      Correction: Indicate in the log the drain cover life span.

      Code ATCP 76.38(2)(b)4. - LIFESPAN

  4. Jun 14, 2023 Routine · 3 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      Flowmeter stuck and can't determine flow rate.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

    • Not serious Non-critical

      SELF-CLOSING AND LATCHING GATES

      The door or gate to the pool enclosure is not self-closing or latching.

      Correction: Repair the door immediately so that it is self-closing and latching. (keep door locked until repaired-there is a second entry that is functioning)

      Code [A] ATCP 76.34(4)

    • Not serious Non-critical

      CRACKS OR PITTING IN THE POOL BASIN

      Pool basin paint coming off.

      Correction: Will need to repaint or resurface pool basin.

      Code [B] ATCP 76.33(1)(a)

Source: Eau Claire City-County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.