Quality Inn
3117 CRAIG RD, Eau Claire, WI 54701 · Eau Claire County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- Eau Claire City-County Health Department
- License / ID
- JHAN-CX5QBN
- Status
- Permitted
- Official record
- Eau Claire City-County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 16 | 5 |
| 2025 | 2 | 29 | 5 |
| 2023 | 2 | 25 | 7 |
Inspections
-
May 6, 2026 Routine · 5 critical, 11 non-critical, 8 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS MAINTAINED CLEAN
Skimmers, gutters, drains not maintained clean. Observed debris build up inside.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
Repeat
STRAINER BASKET NOT CLEANED DAILY
Strainer basket observed soiled with hair/debris build up.
Correction: Clean baskets daily to prevent build up.
Code ATCP 76.11(2)(d) 3. - CLEANED
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN ACTION LEVEL
The combined chlorine plan does not include the combined chlorine action level.
Correction: Includes the combined chlorine action level in the combined chlorine plan.
Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED
-
Not serious
Non-critical
Repeat
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
The pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Observed the pool open for use at time of inspection and PH is less than 7, chlorine is less than 1 PPM.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
TELEPHONE-OTHER TECHNOLOGIES, POWER SUPPLY
Telephone does not have connection and no power.
Correction: Provide a connection to telephone.
Code ATCP 76.26(2)(b)1. - TELEPHONE, OTHER TECHNOLOGIES, POWER
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair.Observed missing/broken tiles of pool deck by pump room door. Multple areas where white floor drains cracke/missing coming away from level flooring.
Correction: Replace/repair all areas to the pool deck that are broken and not maintained in good repair.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
PH
The pH is less than 7.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
WATER CLARITY
Pool water not transparent and free from cloudiness. Main drain grating and outline not readily visible from pool deck. Pool is very cloudy and hard to see the bottom.
Correction: Close the pool until the pool water is transparent and free from cloudiness and so that main drain grating and outline are readily visible from pool deck.
Code ATCP 76.16 (2) - CLARITY
-
Serious
Critical
RESPONSIBLE SUPERVISOR RECORDS MAINTAIN
Responsible supervisor is not ensuring that records are maintained.
Correction: Have the responsible supervisor ensure that records are maintained.
Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE
-
Serious
Critical
Repeat
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided. The drinking fountain does not work and says out of order.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Repeat
-
May 19, 2025 Re-inspection · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
STRAINER BASKET NOT CLEANED DAILY
Strainer basket observed with debris, hair, toys.
Correction: Clean strainer baskets routinely.
Code ATCP 76.11(2)(d) 3. - CLEANED
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
-
May 5, 2025 Routine · 5 critical, 22 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmers, gutters, drains not maintained clean.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
SKIMMER COVERS SECURELY SEATED ON DECK
Skimmer covers not securely seated on deck.
Correction: Ensure that skimmer covers are securely seated on deck.
Code ATCP 76.11(2)(b) 3. - SKIMMER COVERS SECURE ON DECK
-
Not serious
Non-critical
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
STRAINER BASKET NOT CLEANED DAILY
Strainer basket observed with debris, hair, toys.
Correction: Clean strainer baskets routinely.
Code ATCP 76.11(2)(d) 3. - CLEANED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is broken and not being maintained in operating condition.
Correction: Replace the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
PIPING LABELED, TAGGED OR CODED
The piping is not labeled, tagged or color-coded.
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
The pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Testing of the pool is not being completed daily.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
CYANURIC TEST
Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.
Correction: Test water for the cyanuric acid at least once a week.
Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. White drains on side of pool are unlevel and sinking in. Observed multiple tiles missing from pool deck/around basin area.
Correction: Maintain pool deck area in good repair. Manager stated new pool basin is going to be done in November. All missing tiles, sharp edges, cracks should be caulked until pool deck/basin is redone.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
POOL DECK-INDOOR-DISINFECTED
Indoor pool deck area not disinfected at least weekly with disinfecting agents according to the manufacturer’s directions.
Correction: Disinfect indoor pool deck area at least weekly with disinfecting agents according to the manufacturer’s directions. Note: It is recommended to avoid the use of an ammonia-based disinfectant as this can contribute to an increased level of chloramines in the pool water.
Code ATCP 76.33(1)(b)2. - INDOOR DECK DISINFECTED
-
Not serious
Non-critical
DRINKING FOUNTAIN MAINTAINED
The drinking fountain is not in clean and sanitary condition and is leaking.
Correction: Maintain the drinking fountain in clean and sanitary condition.
Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN
-
Not serious
Non-critical
GARBAGE AND REFUSE-SUFFICIENT NUMBER OF CONTAINERS
A sufficient number of containers has not been provided for all garbage and refuse generated.
Correction: Provide a sufficient number of containers for all garbage and refuse generated.
Code ATCP 76.33(3)(b) - NUMBER OF CONTAINERS
-
Not serious
Non-critical
GARBAGE AND REFUSE STORED-PREVENT HARBORAGE
Observed excessive ants crawling on the pool deck.
Correction: Clean pool deck, contact pest control company if ants continue.
Code ATCP 76.33(3)(c) 1. - PREVENTING HARBORAGE
-
Serious
Critical
OPERATOR KNOWLEDGE-MONTHLY TESTING
The person responsible is not able to describe how monthly testing is performed.
Correction: Ensure that operator can describe how monthly testing is performed.
Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING
-
Serious
Critical
RESPONSIBLE SUPERVISOR SANITATION AND TESTING
Responsible supervisor is not ensuring that sanitation and testing is performed.
Correction: Have the responsible supervisor ensure that sanitation and testing duties are performed.
Code ATCP 76.21 (1)(c)4. - SANITAITON AND TESTING
-
Serious
Critical
SHEPHERD'S CROOK PROVIDED
The shepherd's crook is missing.
Correction: Provide a shepherd's crook.
Code ATCP 76.26(1)(b)1.a. -SHEPHERED'S CROOK PROVIDED
-
Serious
Critical
RING BOUY
A ring buoy not provided.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
-
Nov 1, 2023 Re-inspection · 3 critical, 7 non-critical, 10 repeat
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. The pool inlets are faced all to the middle.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
Repeat
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
Repeat
PIPING LABELED, TAGGED OR CODED
The piping is not labeled, tagged or color-coded.
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
Repeat
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. The pool basin has cracks/chips missing tile.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
The ladders going in to the pool are not in good repair and can be pulled out directly from the pool basin.
Correction: Secure ladders to prevent injury.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Multiple areas of pool deck with white trim is cracked/ dips low where someone can hurt there foot. There are cracked/missing tiles rough edges around the pool edge on pool deck.
Correction: Maintain pool deck area in good repair. Fix/repair caulk broken missing tiles/ white trim area around pool to prevent injuries.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
DRINKING FOUNTAIN MAINTAINED
The drinking fountain is not in clean and leaks out the bottom.
Correction: Maintain the drinking fountain in clean and sanitary condition. Fix the leak from bottom of drinking fountain.
Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN
-
Serious
Critical
Repeat
RING BOUY
A ring buoy not provided. [Describe].
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
Repeat
TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION
Telephone in pool area does not have reliable service connection. The phone is static and not working at time of inspection
Correction: Provide a reliable service connection for the communication technology.
Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI
-
Serious
Critical
Repeat
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
Repeat
-
Oct 31, 2023 Pre-inspection · 4 critical, 9 non-critical
-
Not serious
Non-critical
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. The pool inlets are faced all to the middle.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
PIPING LABELED, TAGGED OR CODED
The piping is not labeled, tagged or color-coded.
Correction: Ensure that the piping is labeled, tagged or color-coded to indicate valves, piping and direction of water flow.
Code ATCP 76.11(5m)(a) - PIPING NOT LABELED,TAGGED, CODED
-
Not serious
Non-critical
INTERLOCKED-ELECTRICAL
Power to recirculation system is not interlocked with the power to the chemical feed.
Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).
Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT
-
Not serious
Non-critical
THERMOMETER RETURN LINE
An accurate thermometer is not located in the pool water return line.
Correction: Provide an accurate thermometer in the pool water return line.
Code ATCP 76.19(4)(a)1 - THERMOMETER
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. The pool basin has cracks/chips missing tile.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Multiple areas of pool deck with white trim is cracked/ dips low where someone can hurt there foot. There are cracked/missing tiles rough edges around the pool edge on pool deck.
Correction: Maintain pool deck area in good repair. Fix/repair caulk broken missing tiles/ white trim area around pool to prevent injuries.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
The ladders going in to the pool are not in good repair and can be pulled out directly from the pool basin.
Correction: Secure ladders to prevent injury.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
DRINKING FOUNTAIN MAINTAINED
The drinking fountain is not in clean and leaks out the bottom.
Correction: Maintain the drinking fountain in clean and sanitary condition. Fix the leak from bottom of drinking fountain.
Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN
-
Serious
Critical
Corrected on site
SHEPHERD'S CROOK NON-GUARDED POOL, LONG ENOUGH
The shepherd's crook is missing at time of inspection. The owner found it and it is not connected to be long enough to reach any parts of pool.
Correction: Provide a shepherd's crook that is long enough to effect a rescue in deepest part of pool. Owner found the attachment piece for sheperds crook.
Code ATCP 76.26(1)(b)1.b. - SHEP CROOK LONG ENOUGH NON-GUARDED PO
-
Serious
Critical
RING BOUY
A ring buoy not provided. [Describe].
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION
Telephone in pool area does not have reliable service connection. The phone is static and not working at time of inspection
Correction: Provide a reliable service connection for the communication technology.
Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI
-
Serious
Critical
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
Source: Eau Claire City-County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.