RecordWell Data

Tamarack Condominium

3639 TAMARACK LANE, Eau Claire, WI 54702 · Eau Claire County

13cited violations
2serious tier
5inspections

Establishment

Type
Pool / recreational water (Swimming)
Inspected by
Eau Claire City-County Health Department
License / ID
HSAT-7QXEUL
Status
Permitted
Official record
Eau Claire City-County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026142
2025120
2024250
2023120

Inspections

  1. Jun 22, 2026 Routine · 2 critical, 2 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not in operating condition. Flowmeter is stuck at 80GPM.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Serious Critical

      AUTOMATIC AND CONTINUOUS DISINFECTION

      Pool not automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment. Feeder injector is currently broken but on order. Pool is being hand fed. Chlorine is within limits.

      Correction: Ensure that each pool in use is automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13.

      Code ATCP 76.14 (1) - AUTOMATIC DISINFECTION

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided. Drinking fountain was removed before season due to leaking.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  2. Jun 26, 2025 Routine · 2 non-critical
    • Not serious Non-critical

      LABEL, ACTIVE INGREDIENTS

      Chlorine and acid container labels are worn, and cannot be read.

      Correction: Provide active ingredients on label.

      Code ATCP 76.12 (1)(a) 3. -ACTIVE INGREDIENTS

    • Not serious Non-critical

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

  3. Jun 24, 2024 Routine · 5 non-critical
    • Not serious Non-critical

      LABEL, NAME OF PRODUCT

      Container label does not list name of product.

      Correction: Provide the name of the product on the label.

      Code ATCP 76.12 (1)(a) 1. - PRODUCT NAME

    • Not serious Non-critical

      LABEL, STORE, MIX CHEMICALS, LOCAL, STATE AND FEDERAL COMPLIANCE

      MSDS sheets not provided for all chemicals used in the pools.

      Correction: Comply with applicable local, state, and federal regulations.

      Code ATCP 76.12 - CHEMICALS COMPLIANCE WITH OTHER STATE, FEDERAL,

    • Not serious Non-critical

      POOL RULES SIGNAGE- COMMUNICABLE DISEASE

      Pool rules missing rule: Do not enter the pool if you have a communicable disease or an open cut.

      Correction: Include pool rule on sign: Do not enter the pool if you have a communicable disease or an open cut.

      Code ATCP 76.29(1)(b)1.a - NO COMMUNICABLE DISEASE, OPEN CUT

    • Not serious Non-critical

      POOL RULES SIGNAGE-NO DIAPER CHANGING ON DECK

      Pool rules missing rule: Diaper changing on the pool deck is prohibited.

      Correction: Include pool rule on sign: Diaper changing on the pool deck is prohibited.

      Code ATCP 76.29(1)(b)1.f. - NO DIAPER CHANGING ON DECK

    • Not serious Non-critical

      POSTING SIGNAGE-NO DIVING

      No-Diving signage is not present where it is required.

      Correction: Post signage indicating No-Diving.

      Code ATCP 76.29(1)(d) - NO DIVING

  4. Jun 20, 2024 Routine · No items found

    No violations cited.

  5. Jun 16, 2023 Routine · 2 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      Flowmeter sticking a little and difficult to read.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded. Clean thoroughly and maintain.

      Code ATCP 76.11(5)

    • Not serious Non-critical

      DRINKING FOUNTAIN NOT FUNCTIONAL

      The drinking fountain is not functional.

      Correction: Repair the drinking fountain.Fountain being repaired.

      Code [A] ATCP 76.33(1)(g)

Source: Eau Claire City-County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.