Metropolis Resort
2402 LORCH AVE, Eau Claire, WI 54701 · Eau Claire County
Establishment
- Type
- Pool / recreational water (Leisure River)
- Inspected by
- Eau Claire City-County Health Department
- License / ID
- VRER-CCYR8W
- Status
- Permitted
- Official record
- Eau Claire City-County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 6 | 0 |
| 2025 | 1 | 8 | 0 |
| 2024 | 2 | 3 | 0 |
Inspections
-
Feb 18, 2026 Re-inspection · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 210.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 333 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
Repeat
LIFEGUARD, ATTENDANT STAFFING PLAN-LIFEGUARD LOCATION
On lifeguard staffing plan the locations of the guards for the upper two levels are incomplete.
Correction: Update staffing plan and printed plan to include the levels indicated on Table A and Table B.
Code ATCP 76.22(1)(b)4.- LOCATIONS
-
Not serious
Non-critical
Repeat
-
Feb 4, 2026 Routine · 3 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 210.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 333 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
LIFEGUARD, ATTENDANT STAFFING PLAN-LIFEGUARD LOCATION
On lifeguard staffing plan the locations of the guards for the upper two levels are incomplete.
Correction: Update staffing plan and printed plan to include the levels indicated on Table A and Table B.
Code ATCP 76.22(1)(b)4.- LOCATIONS
-
Not serious
Non-critical
-
Feb 26, 2025 Routine · 8 non-critical
-
Not serious
Non-critical
INCREASED TESTING MAY BE REQUIRED
The water testing logs are not being updated when corrections are made or water chemistry is adjusted.
Correction: Perform any increased testing that the department or its agent has required. Fill logs out completelly for any activity done to pools. if chlorinie or pH adjusted document work done to adjust these levels. Include this on the form that is used in pump room and or if done by lifeguards they can include on their documentation.
Code ATCP 76.18(4) - INCREASED TESTING
-
Not serious
Non-critical
Corrected on site
LIFEGUARD, ATTENDANT STAFFING PLAN-DIAGRAM, PLACEMENT OF LIFEGUARDS
On lifeguard staffing plan -include DATCP cover sheet and placement of additional guards for maximum levels
Correction: Form provided and filled out with additional lifeguard placements
Code ATCP 76.22(1)(b)7.b.- PLACEMENT, LIFEGUARDS
-
Not serious
Non-critical
Corrected on site
SHOWER, TOILET, DRESSING FACILITIES- CLEANED
In shower rooms the tiles along floor level in showers have mop water/cleaning splash build up..
Correction: Clean and disinfect the shower, toilet and dressing facilities daily or more frequently, if necessary to provide clean and sanitary conditions.
Code ATCP 76.33 (2)(a)2. - CLEANED, DISINFECTED
-
Not serious
Non-critical
POOL BASIN MAINTAINED CLEAN AND SANITARY
Pool basin has some sand build up.
Correction: Maintained the pool basin in a clean and sanitary condition.
Code ATCP 76.33(1)(a)3 - POOL BASIN NOT CLEAN AND SANITARY
-
Not serious
Non-critical
POOL DECK-DEPTH MARKINGS MAINTAINED
Pool deck area not maintained so that depth markings along the edge of the pool are clearly visible and readable. Some depth markings are faded or in need of painting.
Correction: Maintain pool deck area so that depth markings along the edge of the pool are clearly visible and readable.
Code ATCP 76.33(1)(b)4. - DEPTH MARKINGS
-
Not serious
Non-critical
WALLS, CEILINGS, FLOORS
The wall near the gorilla wall mural and near the throne collumn by acitivity pool have stains on the wall.
Correction: Maintain the walls, ceilings and floors in a pool area in clean and sanitary condition. Clean these areas or repaint.
Code ATCP 76.33(1)(c) - FLOORS, WALLS, CEILINGS
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The two arms on the pool slide collumn have rust build up and/or paint peeling.
Correction: Maintain the pool equipment -repair rust areas-note that an engineers inspection was done and company hired to fix issues that were noted.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
WATER ATTRACTOIN MAINTENANCE AND REPLACE OR REPAIR
one eye bolt missing connection to rope on childs slide in wade pool
Correction: Connect rope barrier to eye bolt.
Code ATCP 76.37(1)(c)1. - PARTS REPLACED
-
Not serious
Non-critical
-
Jun 28, 2024 Routine · 3 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmers, gutters, drains not maintained clean.
Correction: Maintain the skimmers in clean condition. Routinely check skimmers for debris-toys, and that strainers are in place.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED
Plan is available but front page needs updating due to change in code and new form.
Correction: Update front page of staffing plan Note: A review of plan was done and an attendant was added to plan at the wade pool. Guards in place on leisure and attendant and guard in place for slide and plunge. The view from top of platform can be made of lower run out.
Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR
-
Not serious
Non-critical
WATER ATTRACTOIN MAINTENANCE AND REPLACE OR REPAIR
Areas around slide pillars has rust build up.
Correction: Address rust and monitor for any corrosion that needs to be addressed. At this time secure and just rust visible-no decay ro pieces coming off.
Code ATCP 76.37(1)(c)1. - PARTS REPLACED
-
Not serious
Non-critical
-
Apr 10, 2024 Routine · No items found
No violations cited.
Source: Eau Claire City-County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.