Metropolis Resort

2402 LORCH AVE, Eau Claire, WI 54701 · Eau Claire County

17cited violations
0serious tier
5inspections

Establishment

Type
Pool / recreational water (Leisure River)
Inspected by
Eau Claire City-County Health Department
License / ID
VRER-CCYR8W
Status
Permitted
Official record
Eau Claire City-County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026260
2025180
2024230

Inspections

  1. Feb 18, 2026 Re-inspection · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 210.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 333 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical Repeat

      LIFEGUARD, ATTENDANT STAFFING PLAN-LIFEGUARD LOCATION

      On lifeguard staffing plan the locations of the guards for the upper two levels are incomplete.

      Correction: Update staffing plan and printed plan to include the levels indicated on Table A and Table B.

      Code ATCP 76.22(1)(b)4.- LOCATIONS

  2. Feb 4, 2026 Routine · 3 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 210.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 333 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      LIFEGUARD, ATTENDANT STAFFING PLAN-LIFEGUARD LOCATION

      On lifeguard staffing plan the locations of the guards for the upper two levels are incomplete.

      Correction: Update staffing plan and printed plan to include the levels indicated on Table A and Table B.

      Code ATCP 76.22(1)(b)4.- LOCATIONS

  3. Feb 26, 2025 Routine · 8 non-critical
    • Not serious Non-critical

      INCREASED TESTING MAY BE REQUIRED

      The water testing logs are not being updated when corrections are made or water chemistry is adjusted.

      Correction: Perform any increased testing that the department or its agent has required. Fill logs out completelly for any activity done to pools. if chlorinie or pH adjusted document work done to adjust these levels. Include this on the form that is used in pump room and or if done by lifeguards they can include on their documentation.

      Code ATCP 76.18(4) - INCREASED TESTING

    • Not serious Non-critical Corrected on site

      LIFEGUARD, ATTENDANT STAFFING PLAN-DIAGRAM, PLACEMENT OF LIFEGUARDS

      On lifeguard staffing plan -include DATCP cover sheet and placement of additional guards for maximum levels

      Correction: Form provided and filled out with additional lifeguard placements

      Code ATCP 76.22(1)(b)7.b.- PLACEMENT, LIFEGUARDS

    • Not serious Non-critical Corrected on site

      SHOWER, TOILET, DRESSING FACILITIES- CLEANED

      In shower rooms the tiles along floor level in showers have mop water/cleaning splash build up..

      Correction: Clean and disinfect the shower, toilet and dressing facilities daily or more frequently, if necessary to provide clean and sanitary conditions.

      Code ATCP 76.33 (2)(a)2. - CLEANED, DISINFECTED

    • Not serious Non-critical

      POOL BASIN MAINTAINED CLEAN AND SANITARY

      Pool basin has some sand build up.

      Correction: Maintained the pool basin in a clean and sanitary condition.

      Code ATCP 76.33(1)(a)3 - POOL BASIN NOT CLEAN AND SANITARY

    • Not serious Non-critical

      POOL DECK-DEPTH MARKINGS MAINTAINED

      Pool deck area not maintained so that depth markings along the edge of the pool are clearly visible and readable. Some depth markings are faded or in need of painting.

      Correction: Maintain pool deck area so that depth markings along the edge of the pool are clearly visible and readable.

      Code ATCP 76.33(1)(b)4. - DEPTH MARKINGS

    • Not serious Non-critical

      WALLS, CEILINGS, FLOORS

      The wall near the gorilla wall mural and near the throne collumn by acitivity pool have stains on the wall.

      Correction: Maintain the walls, ceilings and floors in a pool area in clean and sanitary condition. Clean these areas or repaint.

      Code ATCP 76.33(1)(c) - FLOORS, WALLS, CEILINGS

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The two arms on the pool slide collumn have rust build up and/or paint peeling.

      Correction: Maintain the pool equipment -repair rust areas-note that an engineers inspection was done and company hired to fix issues that were noted.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Not serious Non-critical

      WATER ATTRACTOIN MAINTENANCE AND REPLACE OR REPAIR

      one eye bolt missing connection to rope on childs slide in wade pool

      Correction: Connect rope barrier to eye bolt.

      Code ATCP 76.37(1)(c)1. - PARTS REPLACED

  4. Jun 28, 2024 Routine · 3 non-critical
    • Not serious Non-critical

      SKIMMERS MAINTAINED CLEAN

      Skimmers, gutters, drains not maintained clean.

      Correction: Maintain the skimmers in clean condition. Routinely check skimmers for debris-toys, and that strainers are in place.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical

      LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED

      Plan is available but front page needs updating due to change in code and new form.

      Correction: Update front page of staffing plan Note: A review of plan was done and an attendant was added to plan at the wade pool. Guards in place on leisure and attendant and guard in place for slide and plunge. The view from top of platform can be made of lower run out.

      Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR

    • Not serious Non-critical

      WATER ATTRACTOIN MAINTENANCE AND REPLACE OR REPAIR

      Areas around slide pillars has rust build up.

      Correction: Address rust and monitor for any corrosion that needs to be addressed. At this time secure and just rust visible-no decay ro pieces coming off.

      Code ATCP 76.37(1)(c)1. - PARTS REPLACED

  5. Apr 10, 2024 Routine · No items found

    No violations cited.

Source: Eau Claire City-County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.