Metropolis Resort
2402 LORCH AVE, Eau Claire, WI 54701 · Eau Claire County
Establishment
- Type
- Pool / recreational water (Whirlpool)
- Inspected by
- Eau Claire City-County Health Department
- License / ID
- VRER-CCYR7B
- Status
- Permitted
- Official record
- Eau Claire City-County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 0 |
| 2025 | 1 | 0 | 0 |
| 2024 | 2 | 3 | 2 |
Inspections
-
Feb 4, 2026 Routine · 3 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 230.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 183 mV.
Correction: Maintain water potential between 650−900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
There are some missing tiles on rim of pool basin..
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition. Repair missing tiles. Note: A planned maintenance shutdown is scheduled for May.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
-
Feb 26, 2025 Routine · No items found
No violations cited.
-
Jun 28, 2024 Routine · 2 critical, 1 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
Flow meter to be repaired-not working
Correction: Repair flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Chlorine too low for whirlpool.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Provide at least 4ppm chlorine.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The pH is 6.8.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better. CHeck pH with kit and make adjustments.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
-
Apr 10, 2024 Routine · No items found
No violations cited.
Source: Eau Claire City-County Health Department. History last read Oct 15, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.