RecordWell Data

Cottage Grove Commons

2515 GASTON RD, Cottage Grove, WI 53527 · Dane County

15cited violations
0serious tier
5inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2023-00296
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026130
2025130
2024130
2023260

Inspections

  1. Jul 29, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Pool operator manually add Corrected on site

      14c - CHLORINE TOO HIGH (P)

      The chlorine residual exceeded 10 ppm. The free chlorine for the Spa was at 14 ppm at the time of inspection.

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.

      Code ATCP 76.14(4)(f)

    • Not serious Action taken: The ORP went up to 697 mV Corrected on site

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 587 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      30e - SOAP (Pf)

      The soap dispenser in the bathroom shower is empty.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

  2. Jun 24, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Free chlorine was raised t Corrected on site

      14a - CHLORINE TOO LOW (P)

      The chlorine residual was 1.4 ppm at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to [ ]. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken: ORP controller was up duri Corrected on site

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 474 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 70 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

  3. Aug 13, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Pool Operator manually add Corrected on site

      14a - CHLORINE TOO LOW

      The chlorine residual was 0.0ppm at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to [ ]. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 335 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      27c - SIGNAGE - SMALL LETTERS

      The letters on the pool rules signage are less than 1-inch in height.

      Correction: Provide an approved sign.

      Code ATCP 76.29(1)(b)

  4. Jun 12, 2023 Re-Inspection · No Reinspection Required

    No violations cited.

  5. Jun 2, 2023 Pre-Inspection · Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers and the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is 200.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken:

      27c - SIGNAGE - SMALL LETTERS

      The letters on the pool rules signage are less than 1-inch in height.

      Correction: Provide an approved sign.

      Code ATCP 76.29(1)(b)

    • Not serious Signage shall also be conspicuously post

      27f - SIGNAGE - WHIRLPOOL RULES

      The following rules are missing from the posting: no children under 6 years of age allowed.

      Correction: Provide an approved sign.

      Code ATCP 76.29(3)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

    • Not serious Other

      41a - MISCELLANEOUS

      The whirlpool has a 60 minute timer.

      Correction: The whirlpool jet agitation shall be operated by a maximum 15 minute timer.

      Code SPS 390.27(7)

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.