Nov 21, 2025 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: Plan has been started but
16d - COMBINED CHLORINE (Pf) - Not Corrected
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken: New sign on order per oper
27b - SIGNAGE - SUPERVISION OF CHILDREN - Not Corrected
Statement indicating that children under the age of 12 shall be supervised by an adult is now posted, but letters are not at least 1 inch tall.
Correction: Add statement indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b). All letters must be at least one inch in height.
Code ATCP 76.29(1)(c)
-
Not serious
Action taken: Plan has been started but
-
Nov 14, 2025 Re-Inspection · Reinspection Required
-
Not serious
Action taken: Operator ordered spare bas
06a - SPARE STRAINER BASKET - Not Corrected
A spare strainer basket for the skimmers is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected
Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c). Logging of testing interlock not occurring at least once a month.
Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP (Pf) - Not Corrected
The water potential was 268 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV. pH and free chlorine must be tested 4 times a day, including once before opening the whirlpool to guests whenever ORP is not reading 650-900mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
16c - ALKALINITY (Pf) - Not Corrected
The total alkalinity is 30 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf) - Not Corrected
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf) - Not Corrected
At time of reinspection, no daily testing of any kind had been logged since 11/9. Operator states the person doing the testing is keeping the log with him instead of at establishment.
Correction: Perform water testing in accordance with ATCP 76.18(2). Document all test results on log sheet that is kept at establishment.
Code ATCP 76.18(2)
-
Not serious
Action taken: Kit purchased, items still
26r - FIRST AID KIT - SUPPLIES MISSING (Pf) - Not Corrected
All items except for CPR mask are missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Code ATCP 76.27(1)(b)
-
Not serious
Action taken:
27b - SIGNAGE - SUPERVISION OF CHILDREN - Not Corrected
Statement indicating that children under the age of 12 shall be supervised by an adult is now posted, but letters are not at least 1 inch tall.
Correction: Add statement indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b). All letters must be at least one inch in height.
Code ATCP 76.29(1)(c)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected
No documentation is available on site that supports if VGBA equalizer covers were replaced in January 2023 at the same time as other VGBA cover replacements. Other documentation states the equalizer covers expired 12/2024.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Replace covers when beyond expiration date.
Code ATCP 76.38
-
Not serious
Action taken: Operator ordered spare bas
-
Nov 4, 2025 Pre-Inspection · Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket for the skimmers is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Chemical storage room door is not marked to indicate authorized personnel only and a list of emergency numbers was not present in the room.
Correction: Lock doors to chemical storage areas and mark door to indicate entry is for authorized personnel only. Provide a list of emergency telephone numbers in the chemical storage room or have readily available.
Code ATCP 76.12(2)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c). Logging of testing interlock not occurring at least once a month.
Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP (Pf)
The water potential was 569 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV. pH and free chlorine must be tested 4 times a day, including once before opening the whirlpool to guests whenever ORP is not reading 650-900mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 220 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf)
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2).
Correction: Perform water testing in accordance with ATCP 76.18(2). Test combined chlorine daily.
Code ATCP 76.18(2)
-
Not serious
Action taken:
26r - FIRST AID KIT - SUPPLIES MISSING (Pf)
All items except for CPR mask are missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Code ATCP 76.27(1)(b)
-
Not serious
Action taken:
26s - BLANKETS MISSING (Pf)
2 conventional or emergency blankets are not available in the pool area.
Correction: Provide 2 conventional or emergency blankets in the pool area.
Code ATCP 76.27(1)(3)
-
Not serious
Action taken:
26t - BIOHAZARD SAFETY KIT (Pf)
No biohazard safety kit is located at the first aid station or on the premises.
Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)
-
Not serious
Action taken:
27b - SIGNAGE - SUPERVISION OF CHILDREN
Statement indicating that children under the age of 12 shall be supervised by an adult is missing from signage.
Correction: Add statement indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b). All letters must be at least one inch in height.
Code ATCP 76.29(1)(c)
-
Not serious
Any of the following conditions or situa
Corrected on site
28a - CLOSING CRITERIA (P)
The pool was not closed by the operator or responsible supervisor when the free chlorine was less than 3 ppm. Logs showed this occurred for a few days in a row in October, with no notes of closure or corrective action taken. Operator does not know required free chlorine ranges.
Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.
Code ATCP 76.30
-
Not serious
Action taken:
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
A large volume of sand and other debris is present in the corners of the whirlpool basin, indicating likely broken lateral or other repair issue with sand filter.
Correction: Properly maintain and repair equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in the indoor pool area. The carbon monoxide alarm in the pump room is intermittently beeping.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site that supports if VGBA equalizer covers were replaced in January 2023 at the same time as other VGBA cover replacements. Other documentation states the equalizer covers expired 12/2024.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Replace covers when beyond expiration date.
Code ATCP 76.38
-
Not serious
Action taken: