RecordWell Data

Country Inn & Suites

2212 DEMING WAY, Middleton, WI 53590 · Dane County

26cited violations
0serious tier
3inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2025-00737
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20253260

Inspections

  1. Nov 21, 2025 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Plan has been started but

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: New sign on order per oper

      27b - SIGNAGE - SUPERVISION OF CHILDREN - Not Corrected

      Statement indicating that children under the age of 12 shall be supervised by an adult is now posted, but letters are not at least 1 inch tall.

      Correction: Add statement indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b). All letters must be at least one inch in height.

      Code ATCP 76.29(1)(c)

  2. Nov 14, 2025 Re-Inspection · Reinspection Required
    • Not serious Action taken: Operator ordered spare bas

      06a - SPARE STRAINER BASKET - Not Corrected

      A spare strainer basket for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected

      Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c). Logging of testing interlock not occurring at least once a month.

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf) - Not Corrected

      The water potential was 268 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV. pH and free chlorine must be tested 4 times a day, including once before opening the whirlpool to guests whenever ORP is not reading 650-900mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16c - ALKALINITY (Pf) - Not Corrected

      The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf) - Not Corrected

      At time of reinspection, no daily testing of any kind had been logged since 11/9. Operator states the person doing the testing is keeping the log with him instead of at establishment.

      Correction: Perform water testing in accordance with ATCP 76.18(2). Document all test results on log sheet that is kept at establishment.

      Code ATCP 76.18(2)

    • Not serious Action taken: Kit purchased, items still

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf) - Not Corrected

      All items except for CPR mask are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      27b - SIGNAGE - SUPERVISION OF CHILDREN - Not Corrected

      Statement indicating that children under the age of 12 shall be supervised by an adult is now posted, but letters are not at least 1 inch tall.

      Correction: Add statement indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b). All letters must be at least one inch in height.

      Code ATCP 76.29(1)(c)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      No documentation is available on site that supports if VGBA equalizer covers were replaced in January 2023 at the same time as other VGBA cover replacements. Other documentation states the equalizer covers expired 12/2024.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Replace covers when beyond expiration date.

      Code ATCP 76.38

  3. Nov 4, 2025 Pre-Inspection · Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Chemical storage room door is not marked to indicate authorized personnel only and a list of emergency numbers was not present in the room.

      Correction: Lock doors to chemical storage areas and mark door to indicate entry is for authorized personnel only. Provide a list of emergency telephone numbers in the chemical storage room or have readily available.

      Code ATCP 76.12(2)

    • Not serious Action taken:

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c). Logging of testing interlock not occurring at least once a month.

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 569 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV. pH and free chlorine must be tested 4 times a day, including once before opening the whirlpool to guests whenever ORP is not reading 650-900mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 220 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf)

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2).

      Correction: Perform water testing in accordance with ATCP 76.18(2). Test combined chlorine daily.

      Code ATCP 76.18(2)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      All items except for CPR mask are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      26s - BLANKETS MISSING (Pf)

      2 conventional or emergency blankets are not available in the pool area.

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken:

      26t - BIOHAZARD SAFETY KIT (Pf)

      No biohazard safety kit is located at the first aid station or on the premises.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      27b - SIGNAGE - SUPERVISION OF CHILDREN

      Statement indicating that children under the age of 12 shall be supervised by an adult is missing from signage.

      Correction: Add statement indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b). All letters must be at least one inch in height.

      Code ATCP 76.29(1)(c)

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA (P)

      The pool was not closed by the operator or responsible supervisor when the free chlorine was less than 3 ppm. Logs showed this occurred for a few days in a row in October, with no notes of closure or corrective action taken. Operator does not know required free chlorine ranges.

      Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.

      Code ATCP 76.30

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      A large volume of sand and other debris is present in the corners of the whirlpool basin, indicating likely broken lateral or other repair issue with sand filter.

      Correction: Properly maintain and repair equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken:

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in the indoor pool area. The carbon monoxide alarm in the pump room is intermittently beeping.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site that supports if VGBA equalizer covers were replaced in January 2023 at the same time as other VGBA cover replacements. Other documentation states the equalizer covers expired 12/2024.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Replace covers when beyond expiration date.

      Code ATCP 76.38

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.