Country Meadows Apartments
6840 SCHROEDER RD 10, Madison, WI 53711 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 64024-63709
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 13 | 0 |
| 2025 | 1 | 4 | 0 |
| 2024 | 1 | 0 | 0 |
| 2022 | 1 | 0 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Aug 24, 2026 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING (Ppf) - Not Corrected
A pool basin in the facility does not have a 'Warning: No Lifeguard on Duty' sign in minimum 4 inch high letters.
Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.23(2)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected
VGBA documentation indicates that the equalizer covers expired in April 2026.
Correction: 1) Replace equalizer covers "like for like". A change in manufacturer and/or model number requires pre-approval. 2) Operator must log daily inspection of the equalizer covers to ensure no crack, breaks, missing screws or other visible damage or defects are observed. The operator shall close the pool if defects are observed. 3) Maintain documentation (log, receipts, or affidavits from a pool servic
Code ATCP 76.38
-
Not serious
Action taken:
-
Aug 18, 2026 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
08a - RECIRCULATION RATE - SWIM/COMBO (Pf)
The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours. The turnover rate is 6.3 hours.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.
Code ATCP 76.11(4)(c)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Door leading from pool to equipment/chemical storage room is not marked to indicate entry is for authorized personnel only.
Correction: Mark door to indicate entry is for authorized personnel only.
Code ATCP 76.12(2)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Interlock system testing does not include results of the test.
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system. Record test results on log (e.g. pass/fail).
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING (Ppf)
A pool basin in the facility does not have a 'Warning: No Lifeguard on Duty' sign in minimum 4 inch high letters.
Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.23(2)
-
Not serious
Action taken: The pool is ordered closed
26n - TELEPHONE - NOT WORKING (P)
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26r - FIRST AID KIT - SUPPLIES MISSING (Pf)
Elastic bandage is missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Code ATCP 76.27(1)(b)
-
Not serious
Action taken: Operator provided 2 blanke
Corrected on site
26s - BLANKETS MISSING (Pf)
2 conventional or emergency blankets are not available in the pool area.
Correction: Provide 2 conventional or emergency blankets in the pool area.
Code ATCP 76.27(1)(3)
-
Not serious
Any of the following conditions or situa
28a - CLOSING CRITERIA (P)
The pool was not closed by the operator or responsible supervisor under the following condition: emergency phone not working
Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.
Code ATCP 76.30
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
Carbon monoxide alarm in pool equipment room where there is a fuel burning appliance does not work and is expired.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
VGBA documentation indicates that the equalizer covers expired in April 2026.
Correction: 1) Replace equalizer covers "like for like". A change in manufacturer and/or model number requires pre-approval. 2) Operator must log daily inspection of the equalizer covers to ensure no crack, breaks, missing screws or other visible damage or defects are observed. The operator shall close the pool if defects are observed. 3) Maintain documentation (log, receipts, or affidavits from a pool servic
Code ATCP 76.38
-
Not serious
Action taken:
-
Jun 11, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken: Operator replaced batterie
Corrected on site
30e - SOAP (Pf)
The soap dispenser is not working.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken: Operator installed while o
Corrected on site
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken:
-
Jun 13, 2024 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 20, 2022 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 2, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 25, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 24, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 18, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 3, 2016 Routine Inspection · Reinspection Required
No violations cited.
-
Jul 23, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 30, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 10, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 31, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.