RecordWell Data

Downtown 925

925 N 8TH ST, Sheboygan, WI 53081 · Sheboygan County

13cited violations
2serious tier
2inspections

Establishment

Type
Restaurant (retail food serving meals) (Retail Food - Serving Meals)
Inspected by
Sheboygan County Health & Human Services
License / ID
BDAT-DJVKPX
Status
Permitted
Phone
(920) 459-8155
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20252132

Inspections

  1. Nov 18, 2025 Follow Up · 1 priority, 2 priority foundation, 3 core, 6 repeat
    • Serious Priority Repeat

      SEWAGE - BACKFLOW PREVENTION

      A direct connection exists between the sewage system and a drain from 2 compartment vegetable prep sink which is located in the basement. Both basins require an air-gap

      Correction: Design the sewage system in a manner that would preclude a direct connection between the sewage system and the drain from which food is placed. Remove the direct connection.

      Code 5-402.11

    • Not serious Priority Foundation Repeat

      THERMOMETERS - AMBIENT AIR AND WATER - ACCURACY

      Thermometer in all of the cooling units that do not have a built in thermometers measuring ambient air is not accurate to ± 3°F.

      Correction: Calibrate or replace thermometers in all cooling units. Thermometers did not accurately display the proper temperature.

      Code 4-203.12

    • Not serious Priority Foundation Repeat

      WAREWASHING - SANITIZING SOLUTION - TESTING DEVICES

      A Quaternary Ammonium and Chlorine test kit is not available for checking sanitizer concentrations.

      Correction: Provide a test kit or other device for measuring the concentration of sanitizing solutions. The appropriate test kit needs to be located in the area where the sanitizer is being used.

      Code 4-302.14

    • Not serious Core Repeat

      EQUIPMENT AND UTENSILS CONFORM TO ANSI STANDARDS

      Residental (Dorm) Freezer in main floor kitchen and the large white chest freezer in the basement kitchen are not ANSI certified or approved by the department.

      Correction: Unapproved equipment shall be removed from food service. Both freezers are damaged beyond repair and they do not conform to ANSI standards.

      Code 4-205.11

    • Not serious Core Repeat

      FLOOR AND WALL JUNCTURES, COVED, AND ENCLOSED OR SEALED

      Floor and wall juncture in basement areas such as the prep kitchen have areas not coved. The existing coving is vinyl plastic

      Correction: Provide base coving.

      Code 6-201.13 (A)

    • Not serious Core Repeat

      LIGHT BULBS - PROTECTIVE SHIELDING

      Lights located in food preparation areas are not shatter resistant or shielded.

      Correction: Provide shielded, coated, or otherwise shatter resistant light bulbs. Unshielded florescent lights are both T-8 and T-12 types.

      Code 6-202.11

  2. Aug 12, 2025 Pre-inspection · 1 priority, 2 priority foundation, 4 core
    • Serious Priority

      SEWAGE - BACKFLOW PREVENTION

      A direct connection exists between the sewage system and a drain from 2 compartment vegetable prep sink which is located in the basement. Both basins require an air-gap

      Correction: Design the sewage system in a manner that would preclude a direct connection between the sewage system and the drain from which food is placed. Remove the direct connection.

      Code 5-402.11

    • Not serious Priority Foundation

      THERMOMETERS - AMBIENT AIR AND WATER - ACCURACY

      Thermometer in all of the cooling units that do not have a built in thermometers measuring ambient air is not accurate to ± 3°F.

      Correction: Calibrate or replace thermometers in all cooling units. Thermometers did not accurately display the proper temperature.

      Code 4-203.12

    • Not serious Priority Foundation

      WAREWASHING - SANITIZING SOLUTION - TESTING DEVICES

      A Quaternary Ammonium and Chlorine test kit is not available for checking sanitizer concentrations.

      Correction: Provide a test kit or other device for measuring the concentration of sanitizing solutions. The appropriate test kit needs to be located in the area where the sanitizer is being used.

      Code 4-302.14

    • Not serious Core

      CERTIFIED FOOD MANAGER – REQUIREMENT - FOOD ESTABLISHMENTS

      There is no approved or current certified food manager for this establishment.

      Correction: Provide an approved certified food protection manager in the food establishment within 90 Days.

      Code 12-201.11 (A) (1)

    • Not serious Core

      EQUIPMENT AND UTENSILS CONFORM TO ANSI STANDARDS

      Residental (Dorm) Freezer in main floor kitchen and the large white chest freezer in the basement kitchen are not ANSI certified or approved by the department.

      Correction: Unapproved equipment shall be removed from food service. Both freezers are damaged beyond repair and they do not conform to ANSI standards.

      Code 4-205.11

    • Not serious Core

      FLOOR AND WALL JUNCTURES, COVED, AND ENCLOSED OR SEALED

      Floor and wall juncture in basement areas such as the prep kitchen have areas not coved. The existing coving is vinyl plastic

      Correction: Provide base coving.

      Code 6-201.13 (A)

    • Not serious Core

      LIGHT BULBS - PROTECTIVE SHIELDING

      Lights located in food preparation areas are not shatter resistant or shielded.

      Correction: Provide shielded, coated, or otherwise shatter resistant light bulbs. Unshielded florescent lights are both T-8 and T-12 types.

      Code 6-202.11

Source: Sheboygan County Health & Human Services. History last read Oct 17, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.