RecordWell Data

Americinn Of Plymouth-whirlpool

1708 EASTERN AVE, Plymouth, WI 53073 · Sheboygan County

16cited violations
3serious tier
3inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Sheboygan County Health & Human Services
License / ID
HSAT-7QWC4G
Status
Permitted
Phone
(920) 892-2669
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20252133
2023130

Inspections

  1. Sep 24, 2025 Routine · 2 critical, 5 non-critical, 3 repeat
    • Not serious Non-critical Corrected on site

      SKIMMERS MAINTAINED CLEAN

      Skimmer not working - there is no pull or suction and debris is sitting at the bottom of the skimmer.

      Correction: Maintain the skimmers in clean condition. CORRECTED ONSITE: Pump skimmer was cleaned and suction was regained.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not functioning.

      Correction: Adjust or repair the flow meter so that the flow can be properly identified.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing and chemical shut off testing was completed.

      Correction: Record the following on the operating report, the dates when backwashing was and chemical shut off testing completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided within 300 ft.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve.

      Correction: Obtain a pump curve for the whirlpool pump.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  2. Jan 7, 2025 Routine · 1 critical, 5 non-critical
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter float is stuck and is not providing an accurate reading of flow rate.

      Correction: Adjust or repair the flowmeter to provide an accurate reading of flow rate..

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  3. Sep 19, 2023 Routine · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      The weight for the flowmeter is not providing an accurate reading and appears obstructed.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

    • Not serious Non-critical Repeat

      ALKALINITY OUT OF BALANCE

      The total alkalinity is between 20-30 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm. The basin will be dumped due to combined chlorine residuals in the near future with fresh water added.

      Code ATCP 76.14(4)(d)

    • Not serious Non-critical Repeat

      COMBINED CHLORINE

      The combined chlorine is 1.6 ppm.

      Correction: Dump the basin. Dump the whirlpool basin when combined chlorine levels reach or exceed 1.0 ppm

      Code ATCP 76.14(4)(e)

Source: Sheboygan County Health & Human Services. History last read Oct 17, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.