Americinn Of Plymouth-whirlpool
1708 EASTERN AVE, Plymouth, WI 53073 · Sheboygan County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Sheboygan County Health & Human Services
- License / ID
- HSAT-7QWC4G
- Status
- Permitted
- Phone
- (920) 892-2669
- Official record
- Sheboygan County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 2 | 13 | 3 |
| 2023 | 1 | 3 | 0 |
Inspections
-
Sep 24, 2025 Routine · 2 critical, 5 non-critical, 3 repeat
-
Not serious
Non-critical
Corrected on site
SKIMMERS MAINTAINED CLEAN
Skimmer not working - there is no pull or suction and debris is sitting at the bottom of the skimmer.
Correction: Maintain the skimmers in clean condition. CORRECTED ONSITE: Pump skimmer was cleaned and suction was regained.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
Repeat
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not functioning.
Correction: Adjust or repair the flow meter so that the flow can be properly identified.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing and chemical shut off testing was completed.
Correction: Record the following on the operating report, the dates when backwashing was and chemical shut off testing completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided within 300 ft.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve.
Correction: Obtain a pump curve for the whirlpool pump.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Corrected on site
-
Jan 7, 2025 Routine · 1 critical, 5 non-critical
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter float is stuck and is not providing an accurate reading of flow rate.
Correction: Adjust or repair the flowmeter to provide an accurate reading of flow rate..
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets are not available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Sep 19, 2023 Routine · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
The weight for the flowmeter is not providing an accurate reading and appears obstructed.
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
Repeat
ALKALINITY OUT OF BALANCE
The total alkalinity is between 20-30 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm. The basin will be dumped due to combined chlorine residuals in the near future with fresh water added.
Code ATCP 76.14(4)(d)
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE
The combined chlorine is 1.6 ppm.
Correction: Dump the basin. Dump the whirlpool basin when combined chlorine levels reach or exceed 1.0 ppm
Code ATCP 76.14(4)(e)
-
Not serious
Non-critical
Repeat
Source: Sheboygan County Health & Human Services. History last read Oct 17, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.