Sports Core-outdoor Whirlpool
100 WILLOW CREEK DR, Kohler, WI 53044 · Sheboygan County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Sheboygan County Health & Human Services
- License / ID
- HSAT-7QXRLG
- Status
- Permitted
- Phone
- (920) 457-4441
- Official record
- Sheboygan County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 3 | 14 | 7 |
| 2024 | 1 | 3 | 1 |
Inspections
-
Dec 23, 2025 Follow Up · 1 critical, 1 repeat
-
Serious
Critical
Repeat
GATES AND DOORS MECHANISM 54 INCHES
A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door.
Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door in order to prevent small children or other personnel requiring supervision from accessing this area.
Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM
-
Serious
Critical
Repeat
-
Dec 5, 2025 Routine · 3 critical, 4 non-critical, 1 repeat
-
Not serious
Non-critical
INTERLOCKED-ELECTRICAL
Power to recirculation system is not interlocked with the power to the chemical feed.
Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).
Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 30 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Corrected on site
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") was noted at 540 mV at the onset of the inspection.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV. Once the chemical controller was powered on, the ORP was noted at 733 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Serious
Critical
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 3.0 for a non-stabilized public whirlpool using sodium hypochlorite and was noted at <0.2 ppm free chlorine at the onset of the inspection.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. After the chemical controller was powered on, the free chlorine residual was noted at 6.8 ppm during the inspection.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Corrected on site
PH
The pH was 8.0 at the beginning of the whirlpool inspection.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better. After the controller was powered on - the pH was noted at 7.4
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
GATES AND DOORS MECHANISM 54 INCHES
A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door.
Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door in order to prevent small children or other personnel requiring supervision from accessing this area.
Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM
-
Not serious
Non-critical
-
Feb 17, 2025 Routine · 3 critical, 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter weight for the outdoor whirlpool is clogged w/ sand and is not providing a valid reading.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed a written combined chlorine management plan for the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in the whirlpool and the pool water is not tested daily for the combined chlorine level.
Correction: Test pool water daily for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Serious
Critical
Repeat
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Serious
Critical
GATES AND DOORS MECHANISM 54 INCHES
A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. The door leading to the pool/locker room areas is not latching nor lockable.
Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.
Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the drain cover specifications.
Correction: Obtain information that describes make, model and gpm rating for the drain covers per the Virginia Graeme Baker Act.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
May 9, 2024 Routine · 1 critical, 2 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter appears clogged with sand.
Correction: Unclog the flowmeter to provide an accurate reading.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in a whirlpool and pool water is not tested at least daily for the combined chlorine level.
Correction: Test pool water at least daily for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Serious
Critical
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area.
Correction: Provide a first aid kit in the pool area.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
Source: Sheboygan County Health & Human Services. History last read Oct 17, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.