Inspections
-
Jun 12, 2026 Routine · 2 critical
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Serious
Critical
GATES AND DOORS-SELF-CLOSING
The gate or door does not self-close. The hinge is broken that closes the gate.
Correction: Provide a self-closing gate or door.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Serious
Critical
-
May 29, 2025 Routine · 2 critical, 2 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 190 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
POSTING SIGNAGE-NO DIVING
No-Diving signage is not present where it is required.
Correction: Post signage indicating No-Diving.
Code ATCP 76.29(1)(d) - NO DIVING
-
Serious
Critical
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0.8 for Chlorine
Correction: CORRECTED ONSITE: It was discovered that a valve was shut off and not enough water was flowing through the eriosion pucks. This was adjusted and levels were back in range. Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Corrected on site
FREE OF CHEMICAL, PHYSICAL, AND MICROBIAL SUBSTANCES
Main drain was missing a screw from the drain on the east or right side.
Correction: CORRECTED ONSITE: an employee swam down in the pool and replaced the missing screw. Close the pool until the water is free of chemical, physical, and microbial substances known to be, or suspected of being, capable of creating toxic reactions or skin or membrane irritations.
Code ATCP 76.16 (1) - WATER FREE OF PHYSICAL, MICROBIAL
-
Not serious
Non-critical
-
Jun 10, 2024 Routine · 1 critical, 4 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Corrected on site
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
Emergency phone does not provide the location of the facility. CORRECTED: Moving forward this facility will make the forward the main desk when someone picks up the phone. No address of facility near the phone is required due to the phone being directed straight to the receptionist.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Corrected on site
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room. CORRECTED: CO detecors obtained and proof provided during the exit interview 6/14/24.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Jul 27, 2023 Routine · 3 non-critical, 2 repeat
-
Not serious
Non-critical
CYANURIC ACID >30 PPM
The cyanuric acid concentration is over 50 ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Non-critical
Repeat
SKIMMER BASKET OR WEIR MISSING
The skimmer weir doors are missing on all skimmer openings.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
Repeat
FIRST AID SUPPLIES MISSING
8" x 10" gauze pads are missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.
Code [C] ATCP 76.27(1)
-
Not serious
Non-critical