RecordWell Data

Courtyard Apartments

1501 EISNER AVE, Sheboygan, WI 53083 · Sheboygan County

16cited violations
1serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Sheboygan County Health & Human Services
License / ID
HSAT-7QX57Y
Status
Permitted
Phone
(920) 452-2920
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026141
2025140
2024130
2023150

Inspections

  1. Jun 25, 2026 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition and the weight appears stuck within the gauge.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      CHEMICAL FEEDERS USED-AUTOMATIC

      The erosion feeder does not appear to be capable of maintaining the minimum free chlorine residuals. The operator was noted manually adding granular disinfectant to the basin.

      Correction: Repair or replace the chemical feeder so that it is capable of maintaining the proper disinfectant levels (>2.0 ppm).

      Code ATCP 76.13 (1)(b)1. - AUTOMATIC

    • Not serious Non-critical

      POOL WATER TESTED PEAK PATRON LOAD, PH AND SANITIZER

      Pool water not tested for pH and disinfectant at least one other time during the day’s peak patron load. The pool water is not being tested twice a day and documented on the daily monitoring logs

      Correction: Test pool water for pH and disinfectant at least twice per day with one test being conducted before the pool is open and one time during the day’s peak patron load.

      Code ATCP 76.18(1)(a)2 - WATER TESTED, SANITIZER, PH, PEAK LOAD P

    • Serious Critical Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      The minimum free chlorine level for stabilized chlorine pools is 2.0 ppm.

      Correction: Close the pool until disinfectant levels are in compliance with ATCP 76.14 Table A. The free chlorine level of the pool was adjusted during the inspection to above 2.0 ppm.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  2. Jul 7, 2025 Routine · 4 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is ~ 60 ppm.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      The pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use over the weekends.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical Repeat

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical

      SIGNAGE 'NO LIFEGUARD ON DUTY'

      The "No Lifeguard on Duty" font on signage within the pool area is less than 4-inches high.

      Correction: Provide a sign to indicate 'no lifeguard on duty.'

      Code ATCP 76.23(2)- NO LIFEGUARD ON DUTY

  3. Jul 18, 2024 Routine · 3 non-critical
    • Not serious Non-critical

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is 60 ppm.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

  4. Aug 1, 2023 Routine · 5 non-critical, 1 repeat
    • Not serious Non-critical Corrected on site

      RECIRCULATION RATE NOT MET - POOLS

      The swimming pool has a maximum turnover rate of greater than 6 hours. At the time of the inspection the turnover rate was 7.5 hrs.

      Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate. Turnover rate was increased to 5.5 hrs prior to the end of the inspection.

      Code ATCP 76.11(4)(a)

    • Not serious Non-critical Corrected on site

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      At the time of the inspection the flow meter was not working.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded. The flow meter was fixed following todays inspection.

      Code ATCP 76.11(5)

    • Not serious Non-critical Repeat

      WATER TESTING FREQUENCY - POOLS

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Non-critical Corrected on site

      CHLORINE TOO LOW

      The chlorine residual was .6 at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to the minimal allowable limit before re-opening. Chlorine residual was increased to 7.4 ppm following todays inspection.

      Code [A] ATCP 76.14(4)(a)

    • Not serious Non-critical

      SKIMMER BASKET OR WEIR MISSING

      At the time of the inspection the south side skimmer weir flap was missing. In addition, the main drain and equalizer cover documentation was missing. Main drain and equalizer covers appeared in good condition.

      Correction: Replace the missing weir flap. Provide adequate documentation for the main drain and equalizer cover, or replace the covers as soon as possible. Documenation must be provided during the next routine inspection.

      Code [B] ATCP 76.11(2)(b)

Source: Sheboygan County Health & Human Services. History last read Oct 17, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.