The Osthoff Resort - Main Building - Indoor Whirlpool
101 OSTHOFF AVE, Elkhart Lake, WI 53020 · Sheboygan County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Sheboygan County Health & Human Services
- License / ID
- HSAT-7QWSLH
- Status
- Permitted
- Phone
- (920) 876-3366
- Official record
- Sheboygan County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 1 |
| 2025 | 1 | 1 | 0 |
| 2024 | 1 | 6 | 2 |
| 2023 | 1 | 2 | 0 |
Inspections
-
Jun 12, 2026 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
Flow meter is broken. The bobber is stuck and unable to give a measure of the flow.
Correction: Repair or replace the flow meter so that you can obtain an accurate reading of the flow.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
May 29, 2025 Routine · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate is at 0.66 and has not been met.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 0.5h for a whirlpool.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
-
Jun 10, 2024 Routine · 2 critical, 4 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
Turnover rate for the whirlpool is .86. This needs to be at .5 or below.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate 30 minutes.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Corrected on site
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
Emergency phone does not provide the location of the facility. CORRECTED: Moving forward this facility will make the forward the main desk when someone picks up the phone. No address of facility near the phone is required due to the phone being directed straight to the receptionist.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Serious
Critical
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Disinfectant level for chlorine at 1.4 ppm. CORRECTED: sanitizer levels brought up to 3.2
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Corrected on site
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room. CORRECTED: CO detecors obtained and proof provided during the exit interview 6/14/24.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Jul 27, 2023 Routine · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
The flowmeter for the whirlpool is not providing an accurate reading.
Correction: Repair or replace the specified equipment so an accurate reading can be recorded and the whirlpool turnover rate calculated (the turnover must be less than or equal to 30 min.).
Code ATCP 76.11(5)
-
Not serious
Non-critical
Repeat
SKIMMER BASKET OR WEIR MISSING
The weir on the skimmer basket opening has been removed.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
Repeat