Sports Core-indoor Whirlpool

100 WILLOW CREEK DR, Kohler, WI 53044 · Sheboygan County

14cited violations
5serious tier
3inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Sheboygan County Health & Human Services
License / ID
HSAT-7QX3ZC
Status
Permitted
Phone
(920) 457-4441
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20252104
2024141

Inspections

  1. Dec 5, 2025 Routine · 1 critical, 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is less than 50 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Serious Critical Repeat

      GATES AND DOORS MECHANISM 54 INCHES

      A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. The whirlpool area access point is not secured by a locking mechanism.

      Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door to prevent small children or unauthorized personnel from entering the swimming area.

      Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM

  2. Feb 17, 2025 Routine · 3 critical, 4 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      SKIMMER POOL RECIRCULATION FLOW

      The return plumbing for the skimmer baskets and main drains are plumbed together back to the recirculation pump. This set up does not allow for proportional flow whereas 80% of the pool return water is returned through the skimmers.

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer. This repair will require pool plan review through the State Dep. of Safety & Professional Services (DSPS).

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 30 to 40 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed a written combined chlorine management plan for the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool. A template was provided during the inspection.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE

      Chlorine is used in the indoor whirlpool and the pool water is not daily for the combined chlorine level.

      Correction: Test pool water at least daily for the combined chlorine level.

      Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY

    • Serious Critical Repeat

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

    • Serious Critical

      GATES AND DOORS MECHANISM 54 INCHES

      A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. The door leading to the pool & locker room areas are not latching nor lockable.

      Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.

      Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have main drain cover specifications.

      Correction: Obtain information that describes make, model and gpm rating for the drain covers per the Virginia Graeme Baker Act.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  3. May 9, 2024 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      SKIMMER POOL RECIRCULATION FLOW

      The return plumbing for skimmer and main drains are plumbed together preventing 80/20 (percentage: skimmer/main drain) proportional flow for the basin.

      Correction: Submit plans to the State Dep. of Safety & Professional Services for repair. Adjust equipment so that proportion of water recirculating in the basin is 80% from skimmer and 20% from the main drain.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is clogged and not being maintained in a condition that provides an accurate reading.

      Correction: Maintain the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE

      Chlorine is used in the whirlpool and the pool water is not tested at least daily for the combined chlorine level.

      Correction: Test the whirlpool water at least daily for the combined chlorine level.

      Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY

    • Serious Critical

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

Source: Sheboygan County Health & Human Services. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.