RecordWell Data

Lakeview Village Apts

3431-3515 N 10TH, Sheboygan, WI 53083 · Sheboygan County

11cited violations
1serious tier
6inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Sheboygan County Health & Human Services
License / ID
SROE-9K9JH4
Status
Permitted
Phone
(920) 205-9017
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026221
2025140
2024140
2023210

Inspections

  1. Jul 23, 2026 Follow Up · No items found

    No violations cited.

  2. Jun 25, 2026 Routine · 1 critical, 1 non-critical
    • Not serious Non-critical

      AIR MOVEMENT

      A carbon monoxide alarm was sounding within the mechanical room.

      Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement. Investigate the water heater for proper functionality and carbon monoxide hazards. A referral to the fire department will be made.

      Code ATCP 76.33(4)(b) - AIR MOVEMENT

    • Serious Critical

      TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION

      The emergency phone does not have reliable service connection as was not functional during the inspection

      Correction: Repair the emergency phone or provide an alternate communication method to reach emergency services.

      Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI

  3. Jul 7, 2025 Routine · 4 non-critical, 2 repeat
    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      SIGNAGE 'NO LIFEGUARD ON DUTY'

      A pool not required to have a lifeguard, does not have a 'no lifeguard on duty' sign.

      Correction: Provide a sign to indicate 'no lifeguard on duty.'

      Code ATCP 76.23(2)- NO LIFEGUARD ON DUTY

    • Not serious Non-critical Repeat

      POOL RULES SIGNAGE-SHOWER

      Pool rules missing rule: Shower immediately before entering the pool.

      Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.

      Code ATCP 76.29(1)(b)1.c. - SHOWER

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover. The operator has suggested replacing the covers and starting a VGBA drain log.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

  4. Jul 19, 2024 Routine · 4 non-critical
    • Not serious Non-critical

      SIGNAGE 'NO LIFEGUARD ON DUTY'

      A pool not required to have a lifeguard, does not have a 'no lifeguard on duty' sign.

      Correction: Provide a sign to indicate 'no lifeguard on duty.'

      Code ATCP 76.23(2)- NO LIFEGUARD ON DUTY

    • Not serious Non-critical

      POOL RULES SIGNAGE-SHOWER

      Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.

      Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.

      Code ATCP 76.29(1)(b)1.c. - SHOWER

    • Not serious Non-critical

      POOL RULES SIGNAGE-NO DIAPER CHANGING ON DECK

      Pool rules missing rule: Diaper changing on the pool deck is prohibited.

      Correction: Include pool rule on sign: Diaper changing on the pool deck is prohibited.

      Code ATCP 76.29(1)(b)1.f. - NO DIAPER CHANGING ON DECK

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

  5. Sep 5, 2023 Routine · No items found

    No violations cited.

  6. Aug 18, 2023 Follow Up · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      WATER TESTING FREQUENCY - POOLS

      The water testing frequency for Combined Chlorine is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

Source: Sheboygan County Health & Human Services. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.