RecordWell Data

Baymont Inn & Suites-swimming Pool

678 WALTON DR, Plymouth, WI 53073 · Sheboygan County

19cited violations
9serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Sheboygan County Health & Human Services
License / ID
HSAT-7QWDE5
Status
Permitted
Phone
(920) 089-6781
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026173
2025174
2024132
2023120

Inspections

  1. Oct 8, 2026 Routine · 3 critical, 4 non-critical, 2 repeat
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      Flow meter is not functional.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Several dates 2 missing dates for recording pH and Sanitizer in October, and a few in September.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      PH

      The pH is 7.1.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical Repeat

      DRINKING FOUNTAIN PROVIDED

      The drinking fountian has been removed from the pool area.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

    • Serious Critical Repeat

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  2. Sep 12, 2025 Routine · 4 critical, 3 non-critical, 3 repeat
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Serious Critical Repeat

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is inside of a locked pump room.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided in the pool area.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  3. Nov 22, 2024 Routine · 2 critical, 1 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      (NEW THIS YEAR) The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      Please provide the following for your water attraction in regards to VGBA documntation: - VGBA log filled out (provided today) - pump curve - spec sheets for equilizer and main drain - invoice for maindrain and equilizer

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  4. Aug 15, 2023 Routine · 2 non-critical, 1 repeat
    • Not serious Non-critical

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      The flowmeter for the pool was not providing an accurate reading and the float appeared to be stuck.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded (at least 50 GPM).

      Code ATCP 76.11(5)

    • Not serious Non-critical Repeat

      FIRST AID KIT UNAVAILABLE

      A first aid kit is not accessible in the pool area. It is located behind a locked door with missing items noted in the kit.

      Correction: Provide a fully stocked first aid kit in the pool area.

      Code [A] ATCP 76.27(1)

Source: Sheboygan County Health & Human Services. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.