Camp Evelyn
W6598 CAMP EVELYN RD, Plymouth, WI 53073 · Sheboygan County
Establishment
- Type
- Pool / recreational water (Pool - Moderate with Features)
- Inspected by
- Sheboygan County Health & Human Services
- License / ID
- HSAT-7QX3DC
- Status
- Permitted
- Phone
- (920) 946-7108 ext. Abby Weber
- Official record
- Sheboygan County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 0 |
| 2025 | 1 | 2 | 2 |
| 2024 | 1 | 3 | 2 |
| 2023 | 1 | 2 | 0 |
Inspections
-
Jun 10, 2026 Routine · 1 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
-
Jun 5, 2025 Routine · 2 critical, 1 repeat
-
Serious
Critical
Repeat
PH
The pH is 7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Corrected on site
WATER CLARITY
Main drain was observed missing a screw.
Correction: CORRECTED ONSITE: screw was installed Maintain all maindrains with proper screws per manufactuers requirements
Code ATCP 76.16 (2) - CLARITY
-
Serious
Critical
Repeat
-
Jun 28, 2024 Routine · 2 critical, 1 non-critical
-
Not serious
Non-critical
Corrected on site
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 40 ppm. CORRECTED: Adjusted and measured <30 ppm
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Serious
Critical
Corrected on site
PH
The pH is 7.1. CORRECTED: Adjusted and resampled at 7.4
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Corrected on site
-
Jun 8, 2023 Routine · 2 non-critical, 1 repeat
-
Not serious
Non-critical
RECORD RETENTION
VGBA anti-entrapment main drain cover records are not available for review.
Correction: Keep records in accordance with ATCP 76.32(3) and federal law.
Code [A] ATCP 76.32(3)
-
Not serious
Non-critical
Repeat
FIRST AID SUPPLIES MISSING
Items are missing from the first aid kit near the pool.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit and store near the pool area.
Code [C] ATCP 76.27(1)
-
Not serious
Non-critical
Source: Sheboygan County Health & Human Services. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.