12cited violations
4serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Moderate with Features)
Inspected by
Sheboygan County Health & Human Services
License / ID
HSAT-7QXMZS
Status
Permitted
Phone
(920) 893-6911 ext. 1540
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2025394
2024130

Inspections

  1. Oct 20, 2025 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Serious Critical Repeat

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  2. Oct 6, 2025 Routine · 2 critical, 1 non-critical
    • Not serious Non-critical

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Serious Critical

      CERTIFICATION MADE AVAILABLE, LIFEGUARD

      Three of the certifications are expired that are onsite.

      Correction: Make a copy of each certification held by a lifeguard available to the department or its agent.

      Code ATCP 76.22(2)(a) - LIFEGUARD CERTIFICATIONS AVAILABLE

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  3. Feb 5, 2025 Routine · 1 critical, 3 non-critical, 1 repeat
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical Repeat

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      VGBA paper work missing including pump curve, specs, and date of installation.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  4. Jan 8, 2024 Routine · 3 non-critical
    • Not serious Non-critical

      LABEL, CONSPICUOUS

      The pool shock (sodium hypochlorite) bulk storage chemical container is not conspicuously labeled.

      Correction: Provide a conspicuous, easily visible and readable label on the chemical container.

      Code ATCP 76.12 (1)(a)

    • Not serious Non-critical

      CHEMICAL FEEDERS INSTALLED ACCORDING TO DIRECTIONS

      The flow sensor on the chemical feed loop is not operational. Replace sensor and install according to manufacturer's directions.

      Correction: Replace sensor and install according to manufacturer's directions to maintain flow sensing chemical interlock that will prohibit feeding of chemical when flow is not sensed.

      Code ATCP 76.13 (1)(a) - INSTALLED ACCORDING TO DIRECTIONS

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS