Americinn By Wyndham Sheboygan
3664 S TAYLOR DR, Sheboygan, WI 53081 · Sheboygan County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Sheboygan County Health & Human Services
- License / ID
- BDAT-DKPSMJ
- Status
- Permitted
- Phone
- (920) 208-8130
- Official record
- Sheboygan County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 7 | 2 |
| 2025 | 1 | 1 | 0 |
Inspections
-
Aug 27, 2026 Follow Up · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
Repeat
-
Aug 25, 2026 Routine · 2 critical, 4 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter bobbin is stuck in the flowmeter assembly and is not displaying accurate flow rate.
Correction: Clean and service the flowmeter or replace.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 10 PPM.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The ORP is in alarm mode and reading 999. This has caused a disruption in automatic chemical adjustment.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Free chlorine is observed to be less than 0.2 PPM.
Correction: Pool voluntarily closed. Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The pH is less than 7.0. pH indicator is a bright yellow color, below the readable scale.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
-
Aug 25, 2025 Pre-inspection · 1 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical