RecordWell Data

Crystal Lake Golf Course

W6603 CTY RD C, Plymouth, WI 53073 · Sheboygan County

12cited violations
2serious tier
8inspections

Establishment

Type
Restaurant (retail food serving meals) (Retail Food - Serving Meals)
Inspected by
Sheboygan County Health & Human Services
License / ID
BSTR-CFCJD6
Status
Permitted
Phone
(920) 892-4834
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026110
2025200
2024110
20234102

Inspections

  1. May 21, 2026 Routine · 1 core
    • Not serious Core

      CERTIFIED FOOD MANAGER - POSTING OF CERTIFICATE

      There is no approved or current food protection manager’s certificate posted in the food establishment.

      Correction: Post current food protection manager certification in conspicuous view within the food establishment.

      Code 12-201.11 (B)

  2. Apr 16, 2025 Follow Up · No items found

    No violations cited.

  3. Apr 9, 2025 Routine · No items found

    No violations cited.

  4. Mar 20, 2024 Routine · 1 core
    • Not serious Core

      WAREWASHING - MECHANICAL HOT WATER - TEMPERATURE MEASURING DEVICES

      An irreversible registering thermometer is not provided for measuring utensil surface temperatures in the hot water mechanical warewashing operation.

      Correction: Provide an irreversible registering thermometer.

      Code 4-302.13 (B)

  5. Jul 24, 2023 Follow Up · 2 core, 1 repeat
    • Not serious Core

      WAREWASHING - MECHANICAL HOT WATER - TEMPERATURE MEASURING DEVICES

      An irreversible registering thermometer is not provided for measuring utensil surface temperatures in the hot water mechanical warewashing operation.

      Correction: Provide an irreversible registering thermometer.

      Code 4-302.13 (B)

    • Not serious Core Repeat

      PLUMBING - APPROVED SYSTEM

      The plumbing system is not properly designed, constructed or installed. The "Noble" dishwasher waste plumbing is hard plumbed to the building sewer. The waste drainage lines for the soda gun holsters share a drain with the indirect waste plumbing for the ice bins.

      Correction: Design, construct, install, and maintain the plumbing system to conform to the State Uniform Plumbing Code SPS 382. The indirect waste plumbing for a commercial dishwasher shall be installed via air break/gap to the sanitary building drain system (sewer). The indirect waste plumbing for the ice storage bins shall not be installed alongside waste plumbing lines associated with the soda gun drains a

      Code 5-202.11 (A)

  6. Jul 6, 2023 Re-inspection · 1 priority, 2 core, 2 repeat
    • Serious Priority

      FOOD CONTACT SURFACES - MECHANICAL WAREWASHING HOT WATER EXPOSURE TIME

      Sanitization rinse in high-temperature dishmachine does not register a minimum 71°C (160°F) on the irreversible temperature indicator.

      Correction: Adjust exposure time to hot water sanitization rinse so utensils reach a minimum surface temperature of 160°F. Glassware is being sanitized with an iodine solution in the nearby two-compartment sink until the dishwasher is functioning properly.

      Code 4-703.11 (B)

    • Not serious Core Repeat

      WAREWASHING MACHINES - OPERATING INSTRUCTIONS

      The warewashing machine is not operated according to manufacturer's directions.

      Correction: Operate the warewashing machine consistent with the machine’s data plate and other manufacturer’s instructions.

      Code 4-501.15

    • Not serious Core Repeat

      PLUMBING - APPROVED SYSTEM

      The plumbing system is not properly designed, constructed or installed. The "Noble" dishwasher waste plumbing is hard plumbed to the building sewer. The waste drainage lines for the soda gun holsters share a drain with the indirect waste plumbing for the ice bins.

      Correction: Design, construct, install, and maintain the plumbing system to conform to the State Uniform Plumbing Code SPS 382. The indirect waste plumbing for a commercial dishwasher shall be installed via air break to the sanitary building drain system (sewer). The ice storage bins shall not be installed alongside waste plumbing lines and shall terminate above the sanitary building drain system via air-gap.

      Code 5-202.11 (A)

  7. Jun 19, 2023 Follow Up · 2 core, 1 repeat
    • Not serious Core

      WAREWASHING MACHINES - OPERATING INSTRUCTIONS

      The warewashing machine is not operated according to manufacturer's directions.

      Correction: Operate the warewashing machine consistent with the machine’s data plate and other manufacturer’s instructions.

      Code 4-501.15

    • Not serious Core Repeat

      PLUMBING - APPROVED SYSTEM

      The plumbing system is not properly designed, constructed or installed. The "Noble" dishwasher waste plumbing is hard plumbed to the building sewer. The waste drainage lines for the soda gun holsters share a drain with the indirect waste plumbing for the ice bins.

      Correction: Design, construct, install, and maintain the plumbing system to conform to the State Uniform Plumbing Code SPS 382. The indirect waste plumbing for a commercial dishwasher shall be installed via air break to the sanitary building drain system (sewer). The ice storage bins shall not be installed alongside waste plumbing lines and shall terminate above the sanitary building drain system via air-gap.

      Code 5-202.11 (A)

  8. Jun 12, 2023 Routine · 1 priority, 1 priority foundation, 1 core
    • Serious Priority

      FOOD CONTACT SURFACES - SANITIZED BEFORE USE AFTER CLEANING

      Glassware is not being sanitized after cleaning.

      Correction: Clean and sanitize all utensils and equipment before contact with food. Glassware and other food contact surfaces of equipment (tongs, pizza cutter, etc) must be sanitized after cleaning by manual immersion in an approved sanitizer (bleach, quaternary ammonium compound, iodine, acid, or equivalent) for at least 60 seconds and then air-dried.

      Code 4-702.11

    • Not serious Priority Foundation

      HAND DRYING PROVISION

      No single-use toweling is available at employee handwashing sink for hand drying.

      Correction: Provide single-use toweling or other approved devices at employee handwashing sink to facilitate proper handwashing.

      Code 6-301.12

    • Not serious Core

      PLUMBING - APPROVED SYSTEM

      The plumbing system is not properly designed, constructed or installed. The "Noble" dishwasher waste plumbing is hard plumbed to the building sewer. The waste drainage lines for the soda gun holsters share a drain with the indirect waste plumbing for the ice bins.

      Correction: Design, construct, install, and maintain the plumbing system to conform to the State Uniform Plumbing Code SPS 382. The indirect waste plumbing for a commercial dishwasher shall be installed via air break to the sanitary building drain system (sewer). The ice storage bins shall not be installed alongside waste plumbing lines and shall terminate above the sanitary building drain system via air-gap.

      Code 5-202.11 (A)

Source: Sheboygan County Health & Human Services. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.