Crystal Lake Golf Course
W6603 CTY RD C, Plymouth, WI 53073 · Sheboygan County
Establishment
- Type
- Restaurant (retail food serving meals) (Retail Food - Serving Meals)
- Inspected by
- Sheboygan County Health & Human Services
- License / ID
- BSTR-CFCJD6
- Status
- Permitted
- Phone
- (920) 892-4834
- Official record
- Sheboygan County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 0 |
| 2025 | 2 | 0 | 0 |
| 2024 | 1 | 1 | 0 |
| 2023 | 4 | 10 | 2 |
Inspections
-
May 21, 2026 Routine · 1 core
-
Not serious
Core
CERTIFIED FOOD MANAGER - POSTING OF CERTIFICATE
There is no approved or current food protection manager’s certificate posted in the food establishment.
Correction: Post current food protection manager certification in conspicuous view within the food establishment.
Code 12-201.11 (B)
-
Not serious
Core
-
Apr 16, 2025 Follow Up · No items found
No violations cited.
-
Apr 9, 2025 Routine · No items found
No violations cited.
-
Mar 20, 2024 Routine · 1 core
-
Not serious
Core
WAREWASHING - MECHANICAL HOT WATER - TEMPERATURE MEASURING DEVICES
An irreversible registering thermometer is not provided for measuring utensil surface temperatures in the hot water mechanical warewashing operation.
Correction: Provide an irreversible registering thermometer.
Code 4-302.13 (B)
-
Not serious
Core
-
Jul 24, 2023 Follow Up · 2 core, 1 repeat
-
Not serious
Core
WAREWASHING - MECHANICAL HOT WATER - TEMPERATURE MEASURING DEVICES
An irreversible registering thermometer is not provided for measuring utensil surface temperatures in the hot water mechanical warewashing operation.
Correction: Provide an irreversible registering thermometer.
Code 4-302.13 (B)
-
Not serious
Core
Repeat
PLUMBING - APPROVED SYSTEM
The plumbing system is not properly designed, constructed or installed. The "Noble" dishwasher waste plumbing is hard plumbed to the building sewer. The waste drainage lines for the soda gun holsters share a drain with the indirect waste plumbing for the ice bins.
Correction: Design, construct, install, and maintain the plumbing system to conform to the State Uniform Plumbing Code SPS 382. The indirect waste plumbing for a commercial dishwasher shall be installed via air break/gap to the sanitary building drain system (sewer). The indirect waste plumbing for the ice storage bins shall not be installed alongside waste plumbing lines associated with the soda gun drains a
Code 5-202.11 (A)
-
Not serious
Core
-
Jul 6, 2023 Re-inspection · 1 priority, 2 core, 2 repeat
-
Serious
Priority
FOOD CONTACT SURFACES - MECHANICAL WAREWASHING HOT WATER EXPOSURE TIME
Sanitization rinse in high-temperature dishmachine does not register a minimum 71°C (160°F) on the irreversible temperature indicator.
Correction: Adjust exposure time to hot water sanitization rinse so utensils reach a minimum surface temperature of 160°F. Glassware is being sanitized with an iodine solution in the nearby two-compartment sink until the dishwasher is functioning properly.
Code 4-703.11 (B)
-
Not serious
Core
Repeat
WAREWASHING MACHINES - OPERATING INSTRUCTIONS
The warewashing machine is not operated according to manufacturer's directions.
Correction: Operate the warewashing machine consistent with the machine’s data plate and other manufacturer’s instructions.
Code 4-501.15
-
Not serious
Core
Repeat
PLUMBING - APPROVED SYSTEM
The plumbing system is not properly designed, constructed or installed. The "Noble" dishwasher waste plumbing is hard plumbed to the building sewer. The waste drainage lines for the soda gun holsters share a drain with the indirect waste plumbing for the ice bins.
Correction: Design, construct, install, and maintain the plumbing system to conform to the State Uniform Plumbing Code SPS 382. The indirect waste plumbing for a commercial dishwasher shall be installed via air break to the sanitary building drain system (sewer). The ice storage bins shall not be installed alongside waste plumbing lines and shall terminate above the sanitary building drain system via air-gap.
Code 5-202.11 (A)
-
Serious
Priority
-
Jun 19, 2023 Follow Up · 2 core, 1 repeat
-
Not serious
Core
WAREWASHING MACHINES - OPERATING INSTRUCTIONS
The warewashing machine is not operated according to manufacturer's directions.
Correction: Operate the warewashing machine consistent with the machine’s data plate and other manufacturer’s instructions.
Code 4-501.15
-
Not serious
Core
Repeat
PLUMBING - APPROVED SYSTEM
The plumbing system is not properly designed, constructed or installed. The "Noble" dishwasher waste plumbing is hard plumbed to the building sewer. The waste drainage lines for the soda gun holsters share a drain with the indirect waste plumbing for the ice bins.
Correction: Design, construct, install, and maintain the plumbing system to conform to the State Uniform Plumbing Code SPS 382. The indirect waste plumbing for a commercial dishwasher shall be installed via air break to the sanitary building drain system (sewer). The ice storage bins shall not be installed alongside waste plumbing lines and shall terminate above the sanitary building drain system via air-gap.
Code 5-202.11 (A)
-
Not serious
Core
-
Jun 12, 2023 Routine · 1 priority, 1 priority foundation, 1 core
-
Serious
Priority
FOOD CONTACT SURFACES - SANITIZED BEFORE USE AFTER CLEANING
Glassware is not being sanitized after cleaning.
Correction: Clean and sanitize all utensils and equipment before contact with food. Glassware and other food contact surfaces of equipment (tongs, pizza cutter, etc) must be sanitized after cleaning by manual immersion in an approved sanitizer (bleach, quaternary ammonium compound, iodine, acid, or equivalent) for at least 60 seconds and then air-dried.
Code 4-702.11
-
Not serious
Priority Foundation
HAND DRYING PROVISION
No single-use toweling is available at employee handwashing sink for hand drying.
Correction: Provide single-use toweling or other approved devices at employee handwashing sink to facilitate proper handwashing.
Code 6-301.12
-
Not serious
Core
PLUMBING - APPROVED SYSTEM
The plumbing system is not properly designed, constructed or installed. The "Noble" dishwasher waste plumbing is hard plumbed to the building sewer. The waste drainage lines for the soda gun holsters share a drain with the indirect waste plumbing for the ice bins.
Correction: Design, construct, install, and maintain the plumbing system to conform to the State Uniform Plumbing Code SPS 382. The indirect waste plumbing for a commercial dishwasher shall be installed via air break to the sanitary building drain system (sewer). The ice storage bins shall not be installed alongside waste plumbing lines and shall terminate above the sanitary building drain system via air-gap.
Code 5-202.11 (A)
-
Serious
Priority
Source: Sheboygan County Health & Human Services. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.