RecordWell Data

Sports Core-lap Pool

100 WILLOW CREEK DR, Kohler, WI 53044 · Sheboygan County

10cited violations
6serious tier
3inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Sheboygan County Health & Human Services
License / ID
HSAT-7QX399
Status
Permitted
Phone
(920) 457-4441
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2025285
2024121

Inspections

  1. Dec 5, 2025 Routine · 2 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      One of the sand filter pressure gauges was not providing a reading.

      Correction: Adjust or repair the sand filter pressure gauge that is not providing an accurate reading.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Serious Critical Repeat

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

    • Serious Critical Repeat

      GATES AND DOORS MECHANISM 54 INCHES

      A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. Please secure the lap pool swim pool to prevent unauthorized access by minors or other personnel requiring supervision.

      Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.

      Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM

  2. Feb 17, 2025 Routine · 3 critical, 2 non-critical, 1 repeat
    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed a written combined chlorine management plan for the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool. A template was provided during the inspection.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and the pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Serious Critical Repeat

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

    • Serious Critical

      GATES AND DOORS MECHANISM 54 INCHES

      A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. The door to the pool & locker room areas is not latching nor lockable.

      Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.

      Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pool main drain cover specifications.

      Correction: Obtain information that describes make, model and gpm rating for the drain covers per the Virginia Graeme Baker Act.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  3. May 9, 2024 Routine · 1 critical, 1 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter weight appears stuck in the flowmeter

      Correction: Adjust the flowmeter to provide an accurate reading.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Serious Critical

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

Source: Sheboygan County Health & Human Services. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.