Plymouth Aquatic Center - Pool
203 SUHRKE, Plymouth, WI 53073 · Sheboygan County
Establishment
- Type
- Pool / recreational water (Pool - Complex with Features)
- Inspected by
- Sheboygan County Health & Human Services
- License / ID
- HSAT-7QXK7M
- Status
- Permitted
- Phone
- (920) 893-8351 ext. 0
- Official record
- Sheboygan County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 1 | 0 |
| 2025 | 1 | 0 | 0 |
| 2024 | 1 | 2 | 1 |
| 2023 | 1 | 2 | 0 |
Inspections
-
Jun 22, 2026 Admin Follow Up · No items found
No violations cited.
-
Jun 19, 2026 Routine · 1 non-critical
-
Not serious
Non-critical
LIFEGUARD, ATTENDANT STAFFING PLAN-DIAGRAM, PLACEMENT OF LIFEGUARDS
Life guard diagram is not provided for swimming lessons and arobics class where the life guard amount differs from open swim.
Correction: Provide a diagram with each water activity that has different lifeguard configuration including arobics and swimming lessons.
Code ATCP 76.22(1)(b)7.b.- PLACEMENT, LIFEGUARDS
-
Not serious
Non-critical
-
Jul 15, 2025 Routine · No items found
No violations cited.
-
Jul 11, 2024 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Serious
Critical
Corrected on site
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
There is no pump curve available for the circulation pump. CORRECTED: Email sent with all of the VGBA documentation.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Jul 7, 2023 Routine · 2 non-critical
-
Not serious
Non-critical
Corrected on site
SHOWERS, TOILET ROOMS, DRESSING ROOMS NOT CLEAN
The showers/locker room facilities are not being sanitized.
Correction: Clean and disinfect the walls, partitions and floors of showers, toilet rooms and dressing areas in accordance with ATCP 76.33(2)(a). The operator has a quaternary ammonium compound-type sanitizer in stock and will be utilize this product after cleaning the floors to achieve compliance.
Code ATCP 76.33(2)(a)
-
Not serious
Non-critical
IN NEED OF CLEANING
The pool basin is in need of vacuuming. Sand was noted in various areas on the bottom of the basin.
Correction: Keep the facility in a clean condition pursuant to ATCP 76.33(1)(a). Evaluate the source of the sand entering the pool to determine if the source is broken filter louvres, patrons tracking sand into the pool, or potential windblown. In conversations with the operator, they have been experiencing problems with the basin vacuum and are looking into replacing the vacuum.
Code [A] ATCP 76.33(1)(a)
-
Not serious
Non-critical
Corrected on site
Source: Sheboygan County Health & Human Services. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.