RecordWell Data

American Club-wisconsin Room

419 HIGHLAND DR, Kohler, WI 53044 · Sheboygan County

16cited violations
3serious tier
5inspections

Establishment

Type
Restaurant (retail food serving meals) (Retail Food - Serving Meals)
Inspected by
Sheboygan County Health & Human Services
License / ID
BSAW-8J4K6H
Status
Permitted
Phone
(920) 457-8000
Official record
Sheboygan County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026140
2025241
2024282

Inspections

  1. Jun 10, 2026 Routine · 1 priority foundation, 3 core
    • Not serious Priority Foundation Corrected on site

      PROPER COOLING METHODS - CRITERIA

      Improper cooling methods were observed for the cooked potatoes. Cooked potatoes were partially cooled and then combined into 5 ga. containers that were tightly covered. The potatoes were noted 78-92 F within the large containers.

      Correction: Adjust methods or procedures to facilitate cooling as described in 3-501.15. Verify proper cooling through the use of a calibrated food thermometer to assure rapid cooling of food products in the danger zone. The cooked potatoes were placed on sheet pans during the inspection and were noted properly cooling

      Code 3-501.15 (A)

    • Not serious Core

      VENTILATION HOOD SYSTEM - ADEQUACY

      The "Alto Shaam" smoker is not adequately covered by a ventilation hood system.

      Correction: Provide additional ventilation hoods or devices to prevent grease and condensation from collecting on walls and ceilings. Contact the department of safety and professional services for requirements on plan review and installation.

      Code 4-301.14

    • Not serious Core

      NON-FOOD CONTACT SURFACES - CLEAN

      Non-food contact surfaces of the dry food bin exteriors require cleaning. An egg spill was noted on the bottom of the left grill line prep. cooler.

      Correction: Clean and remove dust, dirt, food residue, and other debris from all non-food contact surfaces of equipment.

      Code 4-601.11 (C)

    • Not serious Core

      SEWAGE - OTHER LIQUID WASTES AND RAINWATER

      The indirect waste plumbing for the waitstation ice bin is not installed via air gap prior to the sanitary building drain system (sewer plumbing). Standing water was noted within the ice bin.

      Correction: Provide an air-gap that meets the State Uniform Plumbing Code (SPS 382). The plumbing should be positively pitched to drain properly to prevent stagnant water within the plumbing.

      Code 5-403.12

  2. Jun 16, 2025 Follow Up · No items found

    No violations cited.

  3. Jun 6, 2025 Routine · 1 priority, 1 priority foundation, 2 core, 1 repeat
    • Serious Priority

      FOOD CONTACT SURFACES - SANITIZED BEFORE USE AFTER CLEANING

      The high temperature dishwasher is not achieving a rinse/utensil temperature conducive for sanitizing food contact surfaces.

      Correction: Clean and sanitize all utensils and equipment before contact with food. The final rinse water temperature for a high temperature machine shall be between 180-190F with the utensil surfaces achieving a temperature of at least 160 F. Maintenance was notified of the issue with the high-temperature dishmachine. Provide alternate means of sanitization until the high-temperature dishwasher is functionin

      Code 4-702.11

    • Not serious Priority Foundation Repeat

      ADEQUATE EQUIPMENT FOR TEMPERATURE CONTROL

      The grill line preparatory bay (top & center) is not sufficient in capacity to hold foods at 41 F or less. Breakfast potatoes were noted at 55 F.

      Correction: Provide equipment in sufficient capacity to hold food at proper temperature. Reduce food inventory or provide additional approved equipment. The breakfast potatoes were discarded during the inspection.

      Code 4-301.11

    • Not serious Core

      SEWAGE - OTHER LIQUID WASTES AND RAINWATER

      The indirect waste plumbing for the food preparatory sink does not contain a proper air-gap.

      Correction: Provide a method of draining that meets the State Uniform Plumbing Code (SPS 382).

      Code 5-403.12

    • Not serious Core

      CLEANING, FREQUENCY AND RESTRICTIONS

      Floor areas of the kitchen and waitstaff area have an accumulation of debris & food soiling in hard to reach areas below & behind equipment/shelving.

      Correction: Clean the physical facilities at a frequency necessary to keep them clean.

      Code 6-501.12

  4. Aug 27, 2024 Follow Up · No items found

    No violations cited.

  5. Jun 26, 2024 Routine · 2 priority, 1 priority foundation, 5 core, 1 repeat
    • Serious Priority

      HACCP PLAN - SUPPORTING DOCUMENTS

      Critical limits defined in the approved HACCP plan are not being recorded on approved logs. Equipment temperature logs were unavailable during the inspection. Dates exceed 14-days on product held under refrigeration (raw hamburger on prep. line dated 5-30).

      Correction: Provide supporting documents and any other information as requested by the department or its Agent.

      Code 1-106.12 (E) and (F)

    • Serious Priority

      TCS FOOD - COLD HOLDING

      Half & half was noted at 48°F in a waitress station Pepsi cooler. Cooked potatoes and pooled eggs on the grill line were noted between 48-52 degrees F.

      Correction: Maintain cold time/temperature control for safety food at or below 41°F. Discard unsafe food items.

      Code 3-501.16 (A) (2) AND (B)

    • Not serious Priority Foundation

      ADEQUATE EQUIPMENT FOR TEMPERATURE CONTROL

      The walk-in coolers (production & produce) are not sufficient in capacity to hold foods at 41 F or less. The grill line prep. table w/ ice that is located above the lowboy freezer is not capable of maintaining cold holding food temperatures. Cooked potatoes were noted stored in the produce cooler.

      Correction: Provide equipment in sufficient capacity to hold food at proper temperature. Reduce food inventory or provide additional approved equipment.

      Code 4-301.11

    • Not serious Core

      FOOD CONTAMINATION PREVENTED FROM PREMISE - OFF THE FLOOR

      Working containers of food products (hotel pans) in the both walk-in coolers were noted stored on the floor.

      Correction: Store all food items 6 inches above the floor.

      Code 3-305.11 (A) (3)

    • Not serious Core

      THERMOMETERS - FUNCTIONALITY - EASILY READABLE

      Ambient air-temperature thermometers are located in cooler locations that are not easily readable.

      Correction: Provide ambient air temperature thermomters that are easy to read and placed in visible locations (warmest portion of the cooler).

      Code 4-204.112 (D)

    • Not serious Core

      EQUIPMENT AND UTENSILS CONFORM TO ANSI STANDARDS

      Three beverage coolers (Pepsi) were noted in the kitchen storing perishable food products and are not ANSI certified or approved by the department for such use.

      Correction: Unapproved equipment shall be removed from food service.

      Code 4-205.11

    • Not serious Core Repeat

      WAREWASHING - MECHANICAL HOT WATER - TEMPERATURE MEASURING DEVICES

      An irreversible registering thermometer is not provided for measuring utensil surface temperatures in the hot water mechanical warewashing operation.

      Correction: Provide an irreversible registering thermometer.

      Code 4-302.13 (B)

    • Not serious Core

      NON-FOOD CONTACT SURFACES - CLEAN

      The cooling unit fan guards on the produce walk-in cooler are soiled with dust/mold.

      Correction: Clean and remove dust, dirt, food residue, and other debris from all non-food contact surfaces of equipment.

      Code 4-601.11 (C)

Source: Sheboygan County Health & Human Services. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.