River Hill Inn & Suites
808 DOMINION DR, Hudson, WI 54016 · St. Croix County
Establishment
- Type
- Pool / recreational water (Whirlpool)
- Inspected by
- St. Croix County Public Health
- License / ID
- TSPN-8PGQPL
- Status
- Permitted
- Phone
- (715) 386-8800
- Official record
- St. Croix County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 5 | 1 |
| 2025 | 3 | 12 | 3 |
| 2024 | 1 | 1 | 0 |
| 2023 | 1 | 2 | 0 |
Inspections
-
May 1, 2026 Re-inspection · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Missing grout between basin tiles.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
Repeat
POOL DECK-INDOOR-DISINFECTED
Indoor pool deck area not disinfected at least weekly with disinfecting agents according to the manufacturer’s directions. Owner disinfects every month or two.
Correction: Disinfect indoor pool deck area at least weekly with disinfecting agents according to the manufacturer’s directions. Note: It is recommended to avoid the use of an ammonia-based disinfectant as this can contribute to an increased level of chloramines in the pool water.
Code ATCP 76.33(1)(b)2. - INDOOR DECK DISINFECTED
-
Not serious
Non-critical
Repeat
-
Apr 28, 2026 Routine · 1 critical, 2 non-critical
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Missing grout between basin tiles.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
POOL DECK-INDOOR-DISINFECTED
Indoor pool deck area not disinfected at least weekly with disinfecting agents according to the manufacturer’s directions. Owner disinfects every month or two.
Correction: Disinfect indoor pool deck area at least weekly with disinfecting agents according to the manufacturer’s directions. Note: It is recommended to avoid the use of an ammonia-based disinfectant as this can contribute to an increased level of chloramines in the pool water.
Code ATCP 76.33(1)(b)2. - INDOOR DECK DISINFECTED
-
Serious
Critical
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm. Free chlorine residual is at 12 ppm.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A. (3ppm to 10 ppm)
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Not serious
Non-critical
-
Jul 28, 2025 Follow Up · No items found
No violations cited.
-
Jun 18, 2025 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Underwater light is not operational.
Correction: Maintain the pool equipment Repair or replace underwater light so it is operational.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
-
Apr 30, 2025 Routine · 3 critical, 8 non-critical, 1 repeat
-
Not serious
Non-critical
LABEL, CONSPICUOUS
Chemical container is not conspicuously labeled. Acid tank missing label for Sunnyside muratic acid.
Correction: Provide a conspicuous, easily visible and read label on the chemical container.
Code ATCP 76.12 (1)(a)
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for Sunnyside muratic acid.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
INTERLOCK LOG-MADE AVAILABLE
Log of electronic interlock testing not made available to the department or its agent upon request.
Correction: Make interlock test log available to the department or its agent upon request.
Code ATCP 76.13 (1)(c)4.b - INTERLOCK LOG AVAILABLE
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
TEST KIT APPROVED
Unapproved Taylor 2005C test kit in use.
Correction: Provide a department approved test kit.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. Underwater light is not operational.
Correction: Maintain the pool equipment Repair or replace underwater light so it is operational.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. No pump curve, drain log, or affidavit available.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant for liquid chlorine sanitizer level is 3 PPM. Free Chlorine tested at 1.6 PPM. Taylor test kit has an accuracy of +/- 20%. Free chlorine is between 1.28 - 1.92 PPM.
Correction: Close the pool until liquid chlorine disinfectant level is in compliance with ATCP 76.14 Table A (3-10 PPM).
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
CLOSING CRITERIA-GATE OR DOOR NOT EQUIPPED TO SELF-CLOSE, LATCH, LOCKABLE
The Responsible Supervisor or operator has not closed the pool in the event that a door is not equipped with a self-closing and latching mechanism, except when staffed by a lifeguard or attendant.
Correction: Close the pool in the event of a pool gate or door that is not equipped with a self-closing and latching mechanism, except when staffed by a lifeguard or attendant.
Code ATCP 76.30 (1)(i) - GATE OR DOOR NOT EQUIPPED TO SELF-CLOSE
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
May 9, 2024 Routine · 1 non-critical
-
Not serious
Non-critical
TEST KIT APPROVED
Test kit not aproved. Sanjay took pictures of what chemical test kit to get.
Correction: Get approved chemicals for testing pool water
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
-
May 10, 2023 Routine · 2 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
TEST KIT NOT APPROVED
The test kit used by the facility has not been approved by the department.
Correction: Replace the test kit with one from the approved list.
Code ATCP 76.17(1)
-
Not serious
Non-critical
SKIMMER BASKET OR WEIR MISSING
The west side weir is missing.
Correction: Replace the missing equipment.
Code [B] ATCP 76.11(2)(b)
-
Not serious
Non-critical
Repeat
Source: St. Croix County Public Health. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.