  1. Mar 23, 2026 Follow Up · No items found

    No violations cited.

  2. Feb 23, 2026 Routine · 5 non-critical
    • Serious Critical

      Smoke alarms provided

      Smoke alarms are not provided within each sleeping room (qty 3).

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.

      Code ATCP 72.18(11)(a)

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The basement and two 1rst floor sleeping rooms do not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Bunk beds - guards 5" above mattress

      The top of the guard was less than 5 inches above the top of the mattress of the upper bunk bed in upstaires sleeping room.

      Correction: Reconstruct the top guard or install a thinner mattress to provide at least 5 inches above the top of the mattress.

      Code ATCP 72.18(3)(d)4.a.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram (with 2 evacuation routes to the exterior for each sleeping room) in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Priority Foundation Corrected on site

      Vomit and diarrheal clean-up - written procedures available

      The operator does not have procedures in place for responding to vomiting and diarrheal events. Cleaning procedures provided to owner and placed in renters check in binder.

      Correction: Provide procedures that include clean-up methods and actions employees must take to minimize the spread of contamination and the exposure of employees, consumers, food, and surfaces to vomitus or fecal matter.

      Code ATCP 72.22(4)

  3. Apr 28, 2025 Follow Up · No items found

    No violations cited.

  4. Feb 21, 2025 Pre-inspection · 4 non-critical
    • Not serious Non-critical

      SMOKE DETECTORS - REQUIREMENT

      Smoke detector on the 1st floor and in the basement are expired 12-8-2004.

      Correction: Provide at least one operable non expired smoke detector in the cottage. If a second smoke detector is installed in the basement it cannot be expired past 10 years.

      Code ATCP 72.14 (2) (c)

    • Not serious Non-critical

      WINDOW SCREENING

      Window screens missing in the double bunk 1st floor sleeping room.

      Correction: Provide screening on all windows that can be opened to the outside.

      Code ATCP 72.14 (2) (e)

    • Not serious Non-critical

      PRIVATE WELL-WATER SAMPLED, TESTED, RESULTS AVAILABLE

      A well water sample for serving the public has not been submitted to a certified laboratory for bacteriological analysis.

      Correction: Submit a water sample for every well that serves the public to a certified laboratory for bacteriological analysis and provide the results within 20 business days to the department.

      Code [F] ATCP 72.10 (3)

    • Not serious Non-critical

      FIRE EXITS – REQUIRED NUMBERS

      The Double Bunk 1st floor sleeping room casement windows need handles for proper egress operation of the window. The basement suite sleeping room sill height is at 52" from the floor. The size of the window opening is 20"x30" and meets the minimum code opening of 20"x24". Install a 20"wide x 9" deep permanent platform or fixture such that the flat surface is located no more than 46" directly below the clear egress opening. The basement room called the 4 bunk sleeping room sill height is at 67" from the floor. The size of the window opening is 21"x31" and meets the minimum code opening of 20"x24" but does not meet the 46"-60" sill height as it's 67" from the floor. This basement room cannot be used as a bedroom unless granted a variance approval showing compariable compliance to ATCP 72 code.

      Correction: Referral made to DATCP Rec. for follow-up.

      Code [I] ATCP 72.14 (1)