Rivers Edge Camp Resort
1820 RALEIGH RD, Somerset, WI 54025 · St. Croix County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- St. Croix County Public Health
- License / ID
- TSPN-8PHLY2
- Status
- Permitted
- Phone
- (715) 247-3305
- Official record
- St. Croix County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 1 | 2 | 1 |
| 2024 | 1 | 2 | 1 |
| 2023 | 2 | 3 | 0 |
Inspections
-
Aug 28, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. current at 85 gpm is 6.9 hours[Describe].
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate Flow rate needsto be 97.3 gmp minimum to get 6 hour turnover rate.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
TEST KIT APPROVED
Has Taylor test kit K-2005 which is not titration method for Cl testing
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
-
Aug 14, 2025 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. [Describe].
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Not serious
Non-critical
-
Aug 6, 2024 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
STRAINER BASKET NOT CLEANED DAILY
clean strainer basket cleaned Daily. Also a scum or biofilm buildup
Correction: Clean daily
Code ATCP 76.11(2)(d) 3. - CLEANED
-
Serious
Critical
RING BOUY
A ring buoy not provided.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Not serious
Non-critical
-
Aug 8, 2023 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
CRACKS OR PITTING IN THE POOL BASIN
The pool basin is damaged. Near the steps on west side the pool trim is separating from the pool foundation.
Correction: Repair the pool basin so it is finished and easily cleanable.
Code [B] ATCP 76.33(1)(a)
-
Not serious
Non-critical
Repeat
-
Jun 26, 2023 Routine · 2 non-critical
-
Not serious
Non-critical
pH OUT OF BALANCE
The pH is 7.1.
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Non-critical
CRACKS OR PITTING IN THE POOL BASIN
The pool basin is damaged. Near the steps on west side the pool trim is separating from the pool foundation.
Correction: Repair the pool basin so it is finished and easily cleanable.
Code [B] ATCP 76.33(1)(a)
-
Not serious
Non-critical
Source: St. Croix County Public Health. History last read Oct 18, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.