New Richmond Area Centre
428 S STARR AVE, New Richmond, WI 54017 · St. Croix County
Establishment
- Type
- Pool / recreational water (Pool - Complex with Features)
- Inspected by
- St. Croix County Public Health
- License / ID
- BHEP-7ZFLQE
- Status
- Permitted
- Phone
- (715) 246-2252
- Official record
- St. Croix County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 1 | 2 | 0 |
| 2024 | 2 | 5 | 1 |
Inspections
-
Dec 8, 2025 Routine · 2 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not being maintained in operating condition. It sticks and as to be tapped to get a reading
Correction: Repair the flow meter so it does not have to be tapped to read correct reading.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Not serious
Non-critical
-
Oct 9, 2024 Follow Up · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Please record your readings.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
Repeat
-
Aug 22, 2024 Routine · 1 critical, 2 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Please record your readings.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Serious
Critical
WATER ATTRACTIONS-WATERSLIDES 6 FEET OR HIGHER, INSPECTION
A waterslide 6 feet or higher has not been inspected by an engineer or the signed report from the engineer is missing.
Correction: Have an engineer evaluate the waterslide for the structural stability and integrity of the slide and platform and maintain the signed report from the engineer. Dave is ordering the report.
Code ATCP 76.37(2)(c) - WATERSLIDE INSPECTED BY ENGINEER
-
Not serious
Non-critical
Source: St. Croix County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.