Apple River Family Campground - Upper
345 CHURCHILL RD, Somerset, WI 54025 · St. Croix County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- St. Croix County Public Health
- License / ID
- BHEP-8CCL7Y
- Status
- Permitted
- Phone
- (715) 247-3600
- Official record
- St. Croix County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 2 | 2 |
| 2025 | 2 | 18 | 10 |
| 2024 | 1 | 4 | 2 |
| 2023 | 2 | 3 | 0 |
Inspections
-
Jul 30, 2026 Routine · 2 critical
-
Serious
Critical
GATES AND DOORS MAINTAINED
Gate or door has not been maintained for proper operation. [Describe].
Correction: Maintain the gate or door for proper operation. [Describe].
Code ATCP 76.34(2)(a) - GATES AND DOORS OPERABLE
-
Serious
Critical
GATES AND DOORS MECHANISM 54 INCHES
A self-closing latching and lockable mechanism is not present at least 54 inches from the bottom of the gate or door. [Describe].
Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.
Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM
-
Serious
Critical
-
Jul 23, 2026 Re-inspection · No items found
No violations cited.
-
Aug 22, 2025 Re-inspection · 5 critical, 4 non-critical, 9 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Piping to deep end skimmer is leaking so this line is completely shut off. Repair piping.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Measured volume 28343 / 60 / 74 = 6.4 hours for turnover. Need to be 6.0 hours for turnover. Measured volume 28343 / 60 / 6 = 78.7 gpm needed for flow rate to get 6 hour turnover.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate. I will schedule a reinspection next spring before you open. Work with pool contractor to get the turnover rate corrected.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 50.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-LIFESPAN
The VGBA log or other proof does not indicate drain cover life span.
Correction: Indicate in the log the drain cover life span.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Serious
Critical
Repeat
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Disenfectant level mesured at 1.2 ppm Cl. Minimum disinfectant or sanitizer level is 2.0 for chlorine wth stabalizer.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
PH
The pH is 7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
RING BOUY
A ring buoy not provided.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Aug 15, 2025 Routine · 5 critical, 4 non-critical, 2 repeat
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Piping to deep end skimmer is leaking so this line is completely shut off. Repair piping.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Measured volume 28343 / 60 / 74 = 6.4 hours for turnover. Need to be 6.0 hours for turnover. Measured volume 28343 / 60 / 6 = 78.7 gpm needed for flow rate to get 6 hour turnover.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate. I will schedule a reinspection next spring before you open. Work with pool contractor to get the turnover rate corrected.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 50.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-LIFESPAN
The VGBA log or other proof does not indicate drain cover life span.
Correction: Indicate in the log the drain cover life span.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Serious
Critical
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Disenfectant level mesured at 1.2 ppm Cl. Minimum disinfectant or sanitizer level is 2.0 for chlorine wth stabalizer.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The pH is 7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
RING BOUY
A ring buoy not provided.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Aug 13, 2024 Routine · 2 critical, 2 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met.increae flow rate to get turnover at least 6 hours
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED
The shower, toilet and dressing facilities are not maintained in good repair. Tiles in mens room in handicap toilet and at end of vanity need repair and womes tiles nears service room door and near drain need repair.
Correction: Maintain the shower, toilet and dressing facilities in good repair.
Code ATCP 76.33 (2)(a)1. - GOOD REPAIR
-
Serious
Critical
RING BOUY
A ring buoy not provided.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working or not present.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
-
Aug 16, 2023 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION RATE NOT MET - POOLS
The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.
Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(a)
-
Not serious
Non-critical
Repeat
-
Jun 21, 2023 Routine · 2 non-critical
-
Not serious
Non-critical
RECIRCULATION RATE NOT MET - POOLS
The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.
Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(a)
-
Not serious
Non-critical
CHLORINE TOO LOW
The chlorine residual was o ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to 1.5 or above before re-opening.
Code [A] ATCP 76.14(4)(a)
-
Not serious
Non-critical
Source: St. Croix County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.