814 N KNOWLES AVE, New Richmond, WI 54017 · St. Croix County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- St. Croix County Public Health
- License / ID
- MWIS-BUTK8G
- Status
- Permitted
- Phone
- (715) 246-4606
- Official record
- St. Croix County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 6 | 69 | 17 |
| 2025 | 4 | 29 | 7 |
| 2024 | 4 | 43 | 9 |
Inspections
-
Oct 23, 2026 Re-inspection 2 · 3 critical, 9 non-critical, 12 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Unsure of pool volume but by calculating it from previous rates recorded (702 gallon) turnover rate is ,3
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 220.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. There is a rug over a wooden trap door allowing access to the outside of the pool basin. .
Correction: Maintain pool deck area in good repair [Describe].
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
Repeat
PH
The pH is > 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
SAMPLING-BACTERIOLOGIC STANDARDS, COLIFORM
Analysis of [pathogen] was performed, and [detectable levels] were present in a 100 milliliter sample.
Correction: Close the pool and adjust operation of the pool so that when bacteriological analysis of total coliforms, Staphylococcus aureus, Pseudomonas aeruginosa or Legionella pneumophila is performed, detectable levels are not present in a 100 milliliter sample.
Code ATCP 76.16 (3)(b)1. - PATHOGEN OR INDICATOR DETECTED
-
Serious
Critical
Repeat
GATES AND DOORS LOCKED WHEN POOL NOT OPEN
Gate or door not locked when the pool was not open to the public.
Correction: Lock the gate or door when the pool is not open to the public.
Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED
-
Not serious
Non-critical
Repeat
-
Oct 7, 2026 Follow Up · 3 critical, 9 non-critical, 12 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Unsure of pool volume but by calculating it from previous rates recorded (702 gallon) turnover rate is ,3
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 220.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. There is a rug over a wooden trap door allowing access to the outside of the pool basin. .
Correction: Maintain pool deck area in good repair [Describe].
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
Repeat
PH
The pH is > 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
SAMPLING-BACTERIOLOGIC STANDARDS, COLIFORM
Analysis of [pathogen] was performed, and [detectable levels] were present in a 100 milliliter sample.
Correction: Close the pool and adjust operation of the pool so that when bacteriological analysis of total coliforms, Staphylococcus aureus, Pseudomonas aeruginosa or Legionella pneumophila is performed, detectable levels are not present in a 100 milliliter sample.
Code ATCP 76.16 (3)(b)1. - PATHOGEN OR INDICATOR DETECTED
-
Serious
Critical
Repeat
GATES AND DOORS LOCKED WHEN POOL NOT OPEN
Gate or door not locked when the pool was not open to the public.
Correction: Lock the gate or door when the pool is not open to the public.
Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED
-
Not serious
Non-critical
Repeat
-
Aug 31, 2026 Re-inspection · 3 critical, 9 non-critical, 12 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Unsure of pool volume but by calculating it from previous rates recorded (702 gallon) turnover rate is ,3
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 220.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. There is a rug over a wooden trap door allowing access to the outside of the pool basin. .
Correction: Maintain pool deck area in good repair [Describe].
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
Repeat
PH
The pH is > 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
SAMPLING-BACTERIOLOGIC STANDARDS, COLIFORM
Analysis of [pathogen] was performed, and [detectable levels] were present in a 100 milliliter sample.
Correction: Close the pool and adjust operation of the pool so that when bacteriological analysis of total coliforms, Staphylococcus aureus, Pseudomonas aeruginosa or Legionella pneumophila is performed, detectable levels are not present in a 100 milliliter sample.
Code ATCP 76.16 (3)(b)1. - PATHOGEN OR INDICATOR DETECTED
-
Serious
Critical
Repeat
GATES AND DOORS LOCKED WHEN POOL NOT OPEN
Gate or door not locked when the pool was not open to the public.
Correction: Lock the gate or door when the pool is not open to the public.
Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED
-
Not serious
Non-critical
Repeat
-
Aug 28, 2026 Re-inspection · 3 critical, 9 non-critical, 12 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Unsure of pool volume but by calculating it from previous rates recorded (702 gallon) turnover rate is ,3
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 220.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. There is a rug over a wooden trap door allowing access to the outside of the pool basin. .
Correction: Maintain pool deck area in good repair [Describe].
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
Repeat
PH
The pH is > 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
SAMPLING-BACTERIOLOGIC STANDARDS, COLIFORM
Analysis of [pathogen] was performed, and [detectable levels] were present in a 100 milliliter sample.
Correction: Close the pool and adjust operation of the pool so that when bacteriological analysis of total coliforms, Staphylococcus aureus, Pseudomonas aeruginosa or Legionella pneumophila is performed, detectable levels are not present in a 100 milliliter sample.
Code ATCP 76.16 (3)(b)1. - PATHOGEN OR INDICATOR DETECTED
-
Serious
Critical
Repeat
GATES AND DOORS LOCKED WHEN POOL NOT OPEN
Gate or door not locked when the pool was not open to the public.
Correction: Lock the gate or door when the pool is not open to the public.
Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED
-
Not serious
Non-critical
Repeat
-
Aug 27, 2026 Routine · 3 critical, 9 non-critical, 7 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Unsure of pool volume but by calculating it from previous rates recorded (702 gallon) turnover rate is ,3
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 220.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. There is a rug over a wooden trap door allowing access to the outside of the pool basin. .
Correction: Maintain pool deck area in good repair [Describe].
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
Repeat
PH
The pH is > 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
SAMPLING-BACTERIOLOGIC STANDARDS, COLIFORM
Analysis of [pathogen] was performed, and [detectable levels] were present in a 100 milliliter sample.
Correction: Close the pool and adjust operation of the pool so that when bacteriological analysis of total coliforms, Staphylococcus aureus, Pseudomonas aeruginosa or Legionella pneumophila is performed, detectable levels are not present in a 100 milliliter sample.
Code ATCP 76.16 (3)(b)1. - PATHOGEN OR INDICATOR DETECTED
-
Serious
Critical
GATES AND DOORS LOCKED WHEN POOL NOT OPEN
Gate or door not locked when the pool was not open to the public.
Correction: Lock the gate or door when the pool is not open to the public.
Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED
-
Not serious
Non-critical
Repeat
-
Mar 3, 2026 Re-inspection · 2 critical, 7 non-critical, 8 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Unsure of pool volume but by calculating it from previous rates recorded (702 gallon) turnover rate is ,3
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
CARTRIDGE FILTERS DUPLICATE SET
no replacement filter available
Correction: no replacement filter available
Code ATCP 76.11(6)(d) 3. - DUPLICATE SET
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit. Needs to get guaze roller bandage, adhesive tape, eye wash, elastic bandage, reuscitation face mask, 1 instant cold pack
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. There is a rug over a wooden trap door allowing access to the outside of the pool basin. .
Correction: Maintain pool deck area in good repair. I will need a repair schedule with dates stating when you can complete these repairs.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
Repeat
PH
The pH is 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
GATES AND DOORS LOCKED WHEN POOL NOT OPEN
Gate or door not locked when the pool was not open to the public.
Correction: Lock the gate or door when the pool is not open to the public.
Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED
-
Not serious
Non-critical
Repeat
-
Dec 15, 2025 Re-inspection · 2 critical, 8 non-critical, 8 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The license is not posted for public view. Post behind door
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Unsure of pool volume but by calculating it from previous rates recorded (702 gallon) turnover rate is ,3
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
CARTRIDGE FILTERS DUPLICATE SET
no replacement filter available
Correction: no replacement filter available
Code ATCP 76.11(6)(d) 3. - DUPLICATE SET
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit. Needs to get guaze roller bandage, adhesive tape, eye wash, elastic bandage, reuscitation face mask, 1 instant cold pack
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. There is a rug over a wooden trap door allowing access to the outside of the pool basin. .
Correction: Maintain pool deck area in good repair. I will need a repair schedule with dates stating when you can complete these repairs.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
Repeat
PH
The pH is 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
GATES AND DOORS LOCKED WHEN POOL NOT OPEN
Gate or door not locked when the pool was not open to the public.
Correction: Lock the gate or door when the pool is not open to the public.
Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED
-
Not serious
Non-critical
Repeat
-
Dec 12, 2025 Routine · 2 critical, 7 non-critical, 4 repeat
-
Not serious
Non-critical
LICENSE NOT POSTED
The license is not posted for public view. Post behind door
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
CARTRIDGE FILTERS DUPLICATE SET
no replacement filter available
Correction: Sri says it is in a locked room. Allow us to see the 2 replacemen filters for each pool.
Code ATCP 76.11(6)(d) 3. - DUPLICATE SET
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. Sri given the template to fill out.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit. Needs to get guaze roller bandage, adhesive tape, eye wash, elastic bandage, reuscitation face mask, 1 instant cold pack
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. There is a rug over a wooden trap door allowing access to the outside of the pool basin. .
Correction: Maintain pool deck area in good repair. I will need a repair schedule with dates stating when you can complete these repairs.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 1.0 for free chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
PH
The pH is 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
-
Aug 29, 2025 Re-inspection · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL TEST ONE OTHER TIME DURING PEAK PATRON LOAD, PH AND SANITIZER; NO AUTOMATIC CONTROLLER
Pool water not tested for pH and disinfectant at least two (of the total of 4) times during the day’s peak patron load.
Correction: Test pool water for pH and disinfectant at least two (of the total of 4) times during the day’s peak patron load.
Code ATCP 76.18(2)(a)2.- WATER TESTED TOTAL OF 4 TIMES WHIRLPOOL,
-
Not serious
Non-critical
Repeat
-
Aug 28, 2025 Routine · 3 critical, 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL TEST ONE OTHER TIME DURING PEAK PATRON LOAD, PH AND SANITIZER; NO AUTOMATIC CONTROLLER
Pool water not tested for pH and disinfectant at least two (of the total of 4) times during the day’s peak patron load.
Correction: Test pool water for pH and disinfectant at least two (of the total of 4) times during the day’s peak patron load.
Code ATCP 76.18(2)(a)2.- WATER TESTED TOTAL OF 4 TIMES WHIRLPOOL,
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
OPERATOR KNOWLEDGE-MONTHLY TESTING
The person responsible is not able to describe how monthly testing is performed.
Correction: Ensure that operator can describe how monthly testing and recording of results is performed.
Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Disinfectant or sanitizer level is 0 ppm.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
PH
The pH is > 8.0
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
Repeat
-
Aug 30, 2024 Re-inspection · 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
Aug 16, 2024 Re-inspection · 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
Jul 26, 2024 Re-inspection · 2 critical, 10 non-critical, 12 repeat
-
Not serious
Non-critical
Repeat
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Not tested, no log.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL TEST ONE OTHER TIME DURING PEAK PATRON LOAD, PH AND SANITIZER; NO AUTOMATIC CONTROLLER
Whirlpool water not tested for pH and disinfectant at least two (of the total of 4) times during the day. Not testing, no log.
Correction: Test pool water for pH and disinfectant at least two (of the total of 4) times during the day’s peak patron load.
Code ATCP 76.18(2)(a)2.- WATER TESTED TOTAL OF 4 TIMES WHIRLPOOL,
-
Not serious
Non-critical
Repeat
OPERATOR RESPONSIBILITIES
The operator has not been responsible for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality pursuant.
Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.
Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Repeat
SHEPHERD'S CROOK PIECES SECURELY CONNECTED
The shepherd's crook is not a continuous pole and the pieces are not securely held together.
Correction: Provide a shepherd's crook that is one piece or with sections that are securely connected.
Code ATCP 76.26(1)(b)1.c. - SHEPHERD'S CROOK PIECES SECURELY CONN
-
Serious
Critical
Repeat
GATES AND DOORS-SELF-CLOSING
The door to the pool is patially open/not latched
Correction: Provide a self-closing door, keep door closed.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
Repeat
-
Jul 17, 2024 Routine · 7 critical, 16 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmer weir is wedged in the skimmer drain. Skimmer, skimmer weir and skimmer drain are slimy and light brown colored.
Correction: Maintain the weirs in correct position and maintain skimmers, skimmer weirs, drains in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
REAGENTS REPLACED
Two test kits available, one has expired reagents. The other doesn't appear to have been used.
Correction: Discard all expired reagents.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. Not tested, no log.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Not tested, no log.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL TEST ONE OTHER TIME DURING PEAK PATRON LOAD, PH AND SANITIZER; NO AUTOMATIC CONTROLLER
Whirlpool water not tested for pH and disinfectant at least two (of the total of 4) times during the day. Not testing, no log.
Correction: Test pool water for pH and disinfectant at least two (of the total of 4) times during the day’s peak patron load.
Code ATCP 76.18(2)(a)2.- WATER TESTED TOTAL OF 4 TIMES WHIRLPOOL,
-
Not serious
Non-critical
OPERATOR RESPONSIBILITIES
The operator has not been responsible for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality pursuant.
Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.
Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES
-
Not serious
Non-critical
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY
A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:
Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.
Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS
The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:
Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.
Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
PH
The pH is 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm. Titration of water sample, stopped at 12ppm and sample still hadn't turned.
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Serious
Critical
RESPONSIBLE SUPERVISOR SANITATION AND TESTING
Responsible supervisor is not ensuring that sanitation and testing is performed.
Correction: Have the responsible supervisor ensure that sanitation and testing duties are performed.
Code ATCP 76.21 (1)(c)4. - SANITAITON AND TESTING
-
Serious
Critical
RESPONSIBLE SUPERVISOR RECORDS MAINTAIN
Responsible supervisor is not ensuring that records are maintained. Testing logs not maintained.
Correction: Have the responsible supervisor ensure that records are maintained.
Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE
-
Serious
Critical
SHEPHERD'S CROOK PIECES SECURELY CONNECTED
The shepherd's crook is not a continuous pole and the pieces are not securely held together.
Correction: Provide a shepherd's crook that is one piece or with sections that are securely connected.
Code ATCP 76.26(1)(b)1.c. - SHEPHERD'S CROOK PIECES SECURELY CONN
-
Serious
Critical
RING BOUY
A ring buoy is available but the rope is knotted.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
GATES AND DOORS-SELF-CLOSING
The door to the pool is patially open/not latched
Correction: Provide a self-closing door, keep door closed.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
Source: St. Croix County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.