St. Croix Therapy
742 STERBENZ DR, Hudson, WI 54016 · St. Croix County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- St. Croix County Public Health
- License / ID
- BHEP-8CCLC4
- Status
- Permitted
- Official record
- St. Croix County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 6 | 3 |
| 2025 | 3 | 15 | 6 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Oct 29, 2026 Re-inspection · No items found
No violations cited.
-
Sep 29, 2026 Routine · 3 critical, 3 non-critical
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Alkalinity
Correction: Record the alkalinity on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
Repair the drip at the plastic conduit collar at the sand filter.
Correction: Maintain the pool equipment.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
DRINKING FOUNTAIN MAINTAINED
The drinking fountain is not operational.
Correction: Maintain the drinking fountain in and operable, clean and sanitary condition.
Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN
-
Serious
Critical
Corrected on site
CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS
Horizon Liquiklor 12.5 is not stored separately from Horizon Acid Magic.
Correction: Store oxidizers separately from acids.
Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS
-
Serious
Critical
WATER SUPPLY PROTECTION
Approved backflow or backsiphonage protection does not exist on the potable water hosebib.
Correction: Provide approved backflow and backsiphonage protection at the water supply hose bib.
Code ATCP 76.19(1) - PROTECTION
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Dec 11, 2025 Follow Up · No items found
No violations cited.
-
Oct 29, 2025 Re-inspection · 2 critical, 2 non-critical, 1 repeat
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available. 10-29-25: On backorder.
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. Float is stuck in the flowmeter. Could not test turnover of whirlpool. 10-29-25: Whirlpool is under repair and water drained.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Serious
Critical
CERTIFICATION MADE AVAILABLE, LIFEGUARD
A copy of each certification (AED, First Aid, CPR, and extricating a patient from the water) has not been made available to the department or its agent. 10-29-25: Certification class is scheduled for 11-25-25.
Correction: Make a copy of each certification held by a lifeguard available to the department or its agent.
Code ATCP 76.22(2)(a) - LIFEGUARD CERTIFICATIONS AVAILABLE
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications. No pump curve or VGBA log and affidavit available.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers. Provide a signed VGBA affidavit and VGBA log.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Aug 27, 2025 Routine · 4 critical, 7 non-critical
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. Float is stuck in the flowmeter. Could not test turnover of whirlpool.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for all chemicals used in whirlpool
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Several test kit reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED
No lifeguard or therapy staff staffing plan is available for therapy whirlpool
Correction: Prepare and maintain a lifeguard staffing plan for whirlpool.
Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
WHIRLPOOLS-SIGNAGE POSTED
Whirlpool rules are not posted in the whirlpool area.
Correction: Post the rule for the whirlpool.
Code ATCP 76.29(3) - WHIRLPOOL RULES POSTED
-
Serious
Critical
INTERLOCK LOG-INFORMATION
The monthly testing log is missing or incomplete. Electrical interlock monthly testing log is not maintained.
Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test.
Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED
-
Serious
Critical
CERTIFICATION MADE AVAILABLE, LIFEGUARD
A copy of each certification (AED, First Aid, CPR, and extricating a patient from the water) has not been made available to the department or its agent.
Correction: Make a copy of each certification held by a lifeguard available to the department or its agent.
Code ATCP 76.22(2)(a) - LIFEGUARD CERTIFICATIONS AVAILABLE
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working. The emergency telephone in the accessible office is not operational. Provide a sign for easily locating phone in office.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications. No pump curve or VGBA log and affidavit available.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers. Provide a signed VGBA affidavit and VGBA log.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Aug 27, 2024 Routine · No items found
No violations cited.
-
Jun 5, 2023 Routine · No items found
No violations cited.
Source: St. Croix County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.