Inspections

  1. Oct 29, 2026 Re-inspection · No items found

    No violations cited.

  2. Sep 29, 2026 Routine · 3 critical, 2 non-critical
    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Alkalinity not recorded.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical

      DRINKING FOUNTAIN MAINTAINED

      The drinking fountain is not operational.

      Correction: Maintain the drinking fountain in operable, clean and sanitary condition.

      Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN

    • Serious Critical Corrected on site

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      Horizon Liquiklor 12.5 is not stored separately from Horizon Acid Magic.

      Correction: Store oxidizers separately from acids.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical

      WATER SUPPLY PROTECTION

      Approved backflow or backsiphonage protection does not exist at the potable water supply hose bib.

      Correction: Provide approved backflow and backsiphonage protection at the water supply hose bib.

      Code ATCP 76.19(1) - PROTECTION

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  3. Dec 11, 2025 Follow Up · No items found

    No violations cited.

  4. Oct 29, 2025 Re-inspection · 2 critical, 1 non-critical
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available. 10-29-25: On backorder.

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Serious Critical

      CERTIFICATION MADE AVAILABLE, LIFEGUARD

      A copy of each certification (AED, First Aid, CPR, and extricating a patient from the water) held by each therapy staff member that works with patients in the pool has not been made available to the department or its agent. 10-29-25: Certification class is scheduled for 11-25-25.

      Correction: Make a copy of each certification held by a lifeguard available to the department or its agent.

      Code ATCP 76.22(2)(a) - LIFEGUARD CERTIFICATIONS AVAILABLE

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications. Provide a copy of the pumps pump curve and drain cover specifications. Provide a signed VGBA drain cover affidavit and VGBA drain and cover replacement log. 10-29-25: Maintenance is still in the process of installing drain covers.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  5. Aug 27, 2025 Routine · 3 critical, 9 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers not repaired or replaced as needed. There are 3 of 4 weir doors missing at the pool skimmers.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      INLETS CHECKED AND ADJUSTED

      Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Jets are not adjusted for flow in one uniform distribution pattern.

      Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.

      Code ATCP 76.11(2)(c) - INLETS POSITIONED

    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      SAFETY DATA SHEET

      A safety data sheet was not available for all chemicals

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Several test kit reagents are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED

      No lifeguard and attendant staffing plan is available for in use therapy pool..

      Correction: Prepare and maintain a lifeguard staffing plan.

      Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of electrical interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Serious Critical

      CERTIFICATION MADE AVAILABLE, LIFEGUARD

      A copy of each certification (AED, First Aid, CPR, and extricating a patient from the water) held by each therapy staff member that works with patients in the pool has not been made available to the department or its agent.

      Correction: Make a copy of each certification held by a lifeguard available to the department or its agent.

      Code ATCP 76.22(2)(a) - LIFEGUARD CERTIFICATIONS AVAILABLE

    • Serious Critical

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working. Phones in accessible office in pool room are not operational. Provide a sign in the office above the phone for ease of locating phone in office.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications. Provide a copy of the pumps pump curve and drain cover specifications. Provide a signed VGBA drain cover affidavit and VGBA drain and cover replacement log.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  6. Aug 27, 2024 Routine · 4 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers not repaired or replaced as needed. Weir doors are missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed. Replace weir doors.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE

      Chlorine is used in a [pool] and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY

    • Not serious Non-critical

      POSTING SIGNAGE-SUPERVISION OF CHILDREN

      At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.

      Correction: Post signage stating that children under 12 must be supervised.

      Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

  7. Jun 5, 2023 Routine · No items found

    No violations cited.

Source: St. Croix County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.