Amerivu
814 N KNOWLES AVE, New Richmond, WI 54017 · St. Croix County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- St. Croix County Public Health
- License / ID
- MWIS-BUTK6X
- Status
- Permitted
- Phone
- (715) 246-4606
- Official record
- St. Croix County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 3 | 20 | 5 |
| 2025 | 2 | 14 | 1 |
| 2024 | 4 | 35 | 5 |
Inspections
-
Oct 23, 2026 Routine · 2 critical, 4 non-critical, 1 repeat
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. No record of testing.
Correction: Test pool water at least twice a week for the combined chlorine level. Resutls shall be recoreded on a daily log.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. No record of testing
Correction: Test pool water at least once a week for total alkalinity. Results shall be recored ona daily log.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING FREQUENCY OF TESTING
The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual. No record of testing available.
Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit. Results shall be recorded on a daily log.
Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Lining is coming apart on the side closest to the restroom.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 1.0 Cl, Level is 0 ppm Cl
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
PH
The pH is >8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
-
Aug 27, 2026 Routine · 2 critical, 4 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
PH
The pH is >8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
GATES AND DOORS LOCKED WHEN POOL NOT OPEN
Gate or door not locked when the pool was not open to the public.
Correction: Lock the gate or door when the pool is not open to the public.
Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED
-
Not serious
Non-critical
Repeat
-
Mar 3, 2026 Re-inspection · 1 critical, 7 non-critical, 7 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The license is not posted for public view. Post behind door
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The filter pressure guage is not being maintained in operating condition. It originallywas readin 15 lbs then after Itapped it it read 11 lbs.
Correction: Adjust or repair the pressure guage to filter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
CARTRIDGE FILTERS DUPLICATE SET
no replacement filter available
Correction: Sri says it is in a locked room. Allow us to see the 2 replacemen filters for each pool.
Code ATCP 76.11(6)(d) 3. - DUPLICATE SET
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. Sri given the template to fill out.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit. Needs to get guaze roller bandage, adhesive tape, eye wash, elastic bandage, reuscitation face mask, 1 instant cold pack
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date. Fill out and sign the affidavit
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
GATES AND DOORS LOCKED WHEN POOL NOT OPEN
Gate or door not locked when the pool was not open to the public.
Correction: Lock the gate or door when the pool is not open to the public.
Code ATCP 76.34(2)(c) -GATES OR DOORS LOCKED
-
Not serious
Non-critical
Repeat
-
Dec 12, 2025 Routine · 7 non-critical, 1 repeat
-
Not serious
Non-critical
LICENSE NOT POSTED
The license is not posted for public view. Post behind door
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The filter pressure guage is not being maintained in operating condition. It originallywas readin 15 lbs then after Itapped it it read 11 lbs.
Correction: Adjust or repair the pressure guage to filter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
CARTRIDGE FILTERS DUPLICATE SET
no replacement filter available
Correction: Sri says it is in a locked room. Allow us to see the 2 replacemen filters for each pool.
Code ATCP 76.11(6)(d) 3. - DUPLICATE SET
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. Sri given the template to fill out.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items.
Correction: Replace the missing items in the first aid kit. Needs to get guaze roller bandage, adhesive tape, eye wash, elastic bandage, reuscitation face mask, 1 instant cold pack
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date. Fill out and sign the affidavit
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Not serious
Non-critical
-
Aug 28, 2025 Routine · 1 critical, 6 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
TEST KIT APPROVED
It appears the test kit is not approved as it is not using titrimetric method. I will check to see if this test kit has been approved by the state.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is 27 on one sign and 33 on another sign. Check pool plans and determine what the actual pool patron load is for the swimming pool.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
OPERATOR KNOWLEDGE-MONTHLY TESTING
The person responsible is not performing monthly testing as not recorded
Correction: Ensure that operator can describe how monthly testing is performed.
Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING
-
Not serious
Non-critical
Repeat
-
Aug 30, 2024 Re-inspection · 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
Aug 16, 2024 Re-inspection · 5 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
Jul 26, 2024 Re-inspection · 2 critical, 8 non-critical, 10 repeat
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
Repeat
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer basket for pump not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is 27 on one sign and 33 on another sign. Check pool plans and determine what the actual pool patron load is for the swimming pool.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Repeat
SHEPHERD'S CROOK PIECES SECURELY CONNECTED
The shepherd's crook is not a continuous pole and the pieces are not securely held together.
Correction: Provide a shepherd's crook that is one piece or with sections that are securely connected.
Code ATCP 76.26(1)(b)1.c. - SHEPHERD'S CROOK PIECES SECURELY CONN
-
Serious
Critical
Repeat
GATES AND DOORS-LATCHING
The door to the pool enclosure was not latched/open.
Correction: Provide a latching door, keep closed.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical
Repeat
-
Jul 18, 2024 Routine · 3 critical, 13 non-critical
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmers baskets are not maintained clean.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer basket for pump not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is 27 on one sign and 33 on another sign. Check pool plans and determine what the actual pool patron load is for the swimming pool.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing that are available are the exact same each day and not all records available. Operator indicates they test, then correct chemistry and then record the correct measurements on the log only.
Correction: Record the actual results for chemical testing, if adjustments are made to chemicals then document the corrective action and the new chemical checks on the logs
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY
A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:
Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.
Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS
The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:
Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.
Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
SHEPHERD'S CROOK PIECES SECURELY CONNECTED
The shepherd's crook is not a continuous pole and the pieces are not securely held together.
Correction: Provide a shepherd's crook that is one piece or with sections that are securely connected.
Code ATCP 76.26(1)(b)1.c. - SHEPHERD'S CROOK PIECES SECURELY CONN
-
Serious
Critical
RING BOUY
A ring buoy rope is all knotted up.
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
GATES AND DOORS-LATCHING
The door to the pool enclosure was not latched/open.
Correction: Provide a latching door, keep closed.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical