Baymont By Wyndham Of Baldwin
805 ENERGY DR, Baldwin, WI 54002 · St. Croix County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- St. Croix County Public Health
- License / ID
- HSAT-7QXKAU
- Status
- Permitted
- Phone
- (715) 684-2700
- Official record
- St. Croix County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 3 | 7 | 0 |
| 2025 | 2 | 2 | 0 |
| 2024 | 2 | 2 | 2 |
Inspections
-
Sep 28, 2026 Follow Up · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. All in let jet directional eyeballs missing or in need of repair.
Correction: Repair or replace and adjust jet inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Whirlpool basin has large sections of paint that has chipped and peeled away.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition. Repair within 6 months.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
Repeat
-
Apr 30, 2026 Follow Up · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. All in let jet directional eyeballs missing or in need of repair.
Correction: Repair or replace and adjust jet inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Whirlpool basin has large sections of paint that has chipped and peeled away.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition. Repair within 6 months.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
Repeat
-
Mar 25, 2026 Routine · 3 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Weir door is missing.
Correction: Repair or replace weir door.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. All in let jet directional eyeballs missing or in need of repair.
Correction: Repair or replace and adjust jet inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Whirlpool basin has large sections of paint that has chipped and peeled away.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition. Repair within 6 months.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
-
Feb 14, 2025 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
-
Feb 6, 2025 Routine · 1 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
-
Feb 28, 2024 Re-inspection · No items found
No violations cited.
-
Feb 27, 2024 Routine · 2 critical
-
Serious
Critical
PH
The pH is 8.0
Correction: Maintain the pH at 7.2 to 7.8.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm and is currently 16ppm
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Serious
Critical
Source: St. Croix County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.